Test Report issued under the responsibility of:

TEST REPORT IEC 60598-2-3

Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Report Number. ............................. :

6011995.50

Date of issue ................................. :

2017-07-07

Total number of pages ...................

70 pages (including this page)

Name of Testing Laboratory preparing the Report..................... :

DEKRA Testing and Certification (Shanghai) Ltd. 3/F, #250, Jiangchangsan Road Building 16 Headquarter Economy Park Shibei Hi-Tech Park, Zhabei District Shanghai, P.R.C 200436.

Applicant’s name .......................... :

Philips Lighting (China) Investment Co., Ltd.

Address ......................................... :

Building 9, Lane 888, Tianlin Road, Minhang district, Shanghai, China

Test specification: Standard ........................................ :

IEC 60598-2-3:2002/AMD1:2011 used in conjunction with IEC 60598-1:2014

Test procedure .............................. :

CB Scheme

Non-standard test method ............ :

N/A

Test Report Form No. ................... :

IEC60598_2_3K

Test Report Form(s) Originator .... :

Intertek Semko AB

Master TRF .................................... :

2016-09

Copyright © 2016 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Page 2 of 70

Report No. 6005944.50

Test item description...................... :

LED street lighting

Trade Mark ...................................... :

PHILIPS

Manufacturer................................... :

Philips Lighting (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road, Minhang district, Shanghai, China

Model/Type reference ..................... :

BRP391 series; BRP392 series; BRP394 series (For details please see annex model list)

Ratings ............................................ :

220 - 240 V~; 50 / 60 Hz; 30W to 320 W. (For details please see annex model list)

TRF No. IEC60598_2_3K

Page 3 of 70

Report No. 6005944.50

Responsible Testing Laboratory (as applicable), testing procedure and testing location(s): CB Testing Laboratory:

DEKRA Testing and Certification (Shanghai) Ltd.

Testing location/ address............................: 3F #250 Jiangchangsan Road Building 16 Headquarter Economy Park Shibei Hi-Tech Park, Zhebei District Shanghai, P.R.C 200436. Associated CB Testing Laboratory: Testing location/ address............................: Tested by (name, function, signature) ........: Billy Liu

Approved by (name, function, signature) ...: Lix Li

Testing procedure: TMP/CTF Stage 1: Testing location/ address............................: Tested by (name, function, signature) ........: Approved by (name, function, signature) ...: Testing procedure: WMT/CTF Stage 2: Testing location/ address............................: Tested by (name + signature) .....................: Witnessed by (name, function, signature)..: Approved by (name, function, signature) ...: Testing procedure: SMT/CTF Stage 3 or 4: Testing location/ address............................: Tested by (name, function, signature) ........: Witnessed by (name, function, signature)..: Approved by (name, function, signature) ...: Supervised by (name, function, signature) :

TRF No. IEC60598_2_3K

Page 4 of 70

Report No. 6005944.50

List of Attachments (including a total number of pages in each attachment): N/A

Summary of testing: Tests performed (name of test and test clause): 3186616.50 (original report) All test items have been done in CBTL.

Testing location: DEKRA Testing and Certification (Shanghai) Ltd. 3/F #250 Jiangchangsan Road Building 16 Headquarter Economy Park Shibei Hi-Tech Park, Zhabei District Shanghai, P.R.C 200436

3194952.50 (amendment 1 report) 3.6 (4.13.1) Impact test 3.12 (12.3) Endurance test: 3.13 (9) Resistance to dust, solid objects and moisture 3.15 (13) Resistance to heat, fire and tracking 6005944.50 (amendment 2 report) 3.6 (4.13.1) Impact test 3.12 (12.3) Endurance test: 3.13 (9) Resistance to dust, solid objects and moisture 3.15 (13) Resistance to heat, fire and tracking 6011995.50 (amendment 3 report) No further tests were considered necessary Summary of compliance with National Differences: List of countries addressed: European national differences were considered. The product fulfils the requirements of EN 60598-1:2015; EN 60598-2-3:2003 + A1:2011.

TRF No. IEC60598_2_3K

Page 5 of 70

Report No. 6005944.50

Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.

On enclosure:

Note: 1. The height of graphical symbols shall not be less than 5 mm. The height of letters and numerals either shown separately or with or as part of symbols shall not be less than 2 mm. 2. The symbol combination of WEEE logo shall have a minimum height of 7 mm. 3. The CE marking must be marked on label, manual or packing and have substantially the same vertical dimension, which may not be less than 5 mm if the products would be sold to European Union

TRF No. IEC60598_2_3K

Page 6 of 70

Report No. 6005944.50

Test item particulars .............................................. : -Classification of installation and use..................... : For outdoor use; Class I Supply Connection ................................................ : Terminal block ............................................................................... : -Possible test case verdicts: - test case does not apply to the test object .......... : N/A - test object does meet the requirement ................ : P (Pass) - test object does not meet the requirement .......... : F (Fail) Testing ................................................................... : -Date of receipt of test item ..................................... : 2017-06-26 Date (s) of performance of tests ............................ : 2017-06-26~ 2017-07-05 General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a

comma /

point is used as the decimal separator.

The following standards were considered: IEC 60598-1:2014 IEC 60598-2-3:2002 + A1:2011 EN 60598-1:2015 EN 60598-2-3:2003 + A1: 2011 EN 62471: 2008 Following standards were also considered per the requirement by client IEC 62662:2002 IEC 60529:1989 + A1:1999 + A2:2013 EN 62662:2002 EN 60529:1991 + A1:2000 + A2:2013

TRF No. IEC60598_2_3K

Page 7 of 70

Report No. 6005944.50

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ...........................................................:

Yes Not applicable

When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) ........................ : Philips Luminaires (Chengdu) Co.,Ltd No. 91, Tianyuan Road, Hi-tech, West District, Chengdu City, Sichuan Province, 611730, P.R. China

TRF No. IEC60598_2_3K

Page 8 of 70

Report No. 6005944.50

General product information: The products are LED street lighting including BRP391 series; BRP392 series; BRP394 series. They have similar construction except rated power, dimension and LED driver. Full safety tests and IK08 test were performed on model no. BRP394 LED384/NW 320W 220-240V DM PSU due to its maximum power consumption (320W). In addition to the above tests, the following tests also are taken into account. Construction check was performed on model BRP392 LED192/NW 160W 220-240V DM PSR and model no.BRP391 LED60/NW 50W 220-240V DM PSU due to their different construction as model no. BRP394 LED384/NW 320W 220-240V DM PSU IK08 test was also carried out on model no. BRP391 LED96/NW 80W 220-240V DM PSU as per IEC 62662 due to its minimum dimension. IP66 test was carried out on model no.BRP394 LED384/NW 320W 220-240V DM PSU as per IEC 60529 due to their maximum power consumption and dimension. And model no. BRP391 LED96/NW 80W 220240V DM PSU also be considered because its minimum dimension The endurance test and thermal test are also performed on model no.BRP392 LED192/NW 160W 220240V DM PSR and model no.BRP391 LED60/NW 50W 220-240V DM PSU due to their different dimension as model no. BRP394 LED384/NW 320W 220-240V DM PSU Static load test also performed on model no.BRP392 LED192/NW 160W 220-240V DM PSR and model no.BRP391 LED60/NW 50W 220-240V DM PSU due to their different dimension as model no. BRP394 LED384/NW 320W 220-240V DM PSU The products were tested according to IEC 62471:2006; EN 62471:2008; IEC/TR 62778:2014 and classified as RG1. Refer to DEKRA test report 3186617.50A and 3186617.50B. The products complied with EN 62493:2010. Refer to DEKRA test report 3186618.10. The products complied with IEC 62662:2002, IEC 60529:1989 + A1:1999 + A2:2013, EN 62662:2002 and EN 60529:1991 + A1:2000 + A2:2013. Refer to DEKRA test report 3186616.50QS

TRF No. IEC60598_2_3K

Page 9 of 70

Report No. 6005944.50

Amendment 1 report: The original Test report Ref. No. 3186616.50, dated 2016-06-02 and NL-41688 dated 2016-06-08 were replaced to include the following additions and changes. --Original SPD was replaced by a new one and listed in CDF with bold letter. --add some models with PE cell. Added models have same construction as original models except appearance (with PE cell), so endurance test ,material test and IP66 test were carried out on BRP394 LED384/NW 320W 220-240V DM PSR P1 After review, all tests have been done. The products were tested according to IEC 62471:2006; EN 62471:2008; IEC/TR 62778:2014 and classified as RG1. Refer to DEKRA test report 3194953.50P. The products complied with EN 62493:2010. Refer to DEKRA test report 3194954.10. The products complied with IEC 62662:2002, IEC 60529:1989 + A1:1999 + A2:2013, EN 62662:2002 and EN 60529:1991 + A1:2000 + A2:2013. Refer to DEKRA test report 3194952.50QS Amendment 2 report: The original Test report Ref. No. 3194952.50, dated 2016-09-20 and NL-43389 dated 2016-09-21 were replaced to include the following additions and changes. - Products with CityTouch function are added - Certificated drivers and controller are added and listed in “Critical components information” with bold letters - Manual and model list are updated. After review, tests specified in “Summary of Testing” are carried out on model no. BRP394 LED384/NW 320W 220-240V DM PSR P7 CT. The products complied with EN 62493:2010. Refer to DEKRA test report 6005945.10. Amendment 3 report: The original Test report Ref. No. 6005944.50, dated 2017-04-21 and NL-46464 dated 2017-04-24 were replaced to include the following additions and changes. - Update the explanation of model list as per requirement by client. - Add some models and list in model list with bold letters New models are fully same construction as originals except model type. After review, no tests were considered necessary. The products were tested according to IEC/TR 62778:2014 and classified as RG1. Refer to DEKRA test report 6011996.50P. The products complied with EN 62493:2010 and EN 62493:2015. Refer to DEKRA test report 6011997.10.

TRF No. IEC60598_2_3K

Page 10 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.2 (0)

GENERAL TEST REQUIREMENTS

3.2 (0.1)

Information for luminaire design considered ............ :

Standard Yes No



3.2 (0.3)

More sections applicable ........................................ :

Yes



3.4 (2)

CLASSIFICATION

3.4 (2.2)

Type of protection .................................................. :

Class I



3.4 (2.3)

Degree of protection ............................................... :

IP66



3.4 (2.4)

Luminaire suitable for direct mounting on normally flammable surfaces ................................................ :

Yes

No



3.4 (2.5)

Luminaire for normal use ....................................... :

Yes

No



Luminaire for rough service .................................... :

Yes

No



3.4 (-)

Result - Remark

Verdict

P

No

P



Modes of installation of road or street lighting a) on a pipe

Yes

No



b) on a mast arm

Yes

No



c) on a post top

Yes

No



d) on span or suspension wires

Yes

No



e) on a wall

Yes

No



3.5 (3)

MARKING

P

3.5 (3.2)

Mandatory markings

P

Position of the marking

P

Format of symbols/text

P

Additional information

P

Language of instructions

P

3.5 (3.3.1)

Combination luminaires

N/A

3.5 (3.3.2)

Nominal frequency in Hz

P

3.5 (3.3.3)

Operating temperature

N/A

3.5 (3.3.4)

Symbol or warning notice

N/A

3.5 (3.3.5)

Wiring diagram

3.5 (3.3.6)

Special conditions

N/A

3.5 (3.3.7)

Metal halide lamp luminaire – warning

N/A

3.5 (3.3.8)

Limitation for semi-luminaires

N/A

3.5 (3.3)

TRF No. IEC60598_2_3K

P

Page 11 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.5 (3.3.9)

Power factor and supply current

Result - Remark

Verdict P

3.5 (3.3.10) Suitability for use indoors

N/A

3.5 (3.3.11) Luminaires with remote control

N/A

3.5 (3.3.12) Clip-mounted luminaire – warning

N/A

3.5 (3.3.13) Specifications of protective shields

N/A

3.5 (3.3.14) Symbol for nature of supply

P

3.5 (3.3.15) Rated current of socket outlet

N/A

3.5 (3.3.16) Rough service luminaire

N/A

3.5 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments

N/A

3.5 (3.3.18) Non-ordinary luminaires with PVC cable

N/A

3.5 (3.3.19) Protective conductor current in instruction if applicable

N/A

3.5 (3.3.20) Provided with information if not intended to be mounted within arm’s reach

N/A

3.5 (3.3.21) Non-replaceable and non-user replaceable light sources information provided Cautionary symbol 3.5 (3.3.22) Controllable luminaires, classification of insulation provided 3.5 (3.4)

3.5 (-)

P N/A N/A

Test with water

P

Test with hexane

P

Legible after test

P

Label attached

P

Additional information in instruction leaflet

P

a) Design attitude

P

b) Weight

P

c) Overall dimensions

P

d) Maximum projected area if applicable

P

e) Cross-sectional area of wires if applicable f) Suitability for indoors use g) Dimensions of the compartment

N/A P N/A

h) Torque setting to be applied to bolts or screws

P

i) Maximum mounting height

P

TRF No. IEC60598_2_3K

Page 12 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.6 (4)

CONSTRUCTION

3.6 (4.2)

Components replaceable without difficulty

3.6 (4.3)

Wireways smooth and free from sharp edges

3.6 (4.4)

Lampholders

N/A

3.6 (4.4.1)

Integral lampholder

N/A

3.6 (4.4.2)

Wiring connection

N/A

3.6 (4.4.3)

Lampholder for end-to-end mounting

N/A

3.6 (4.4.4)

Positioning

N/A

- pressure test (N) .................................................. :

Result - Remark

Verdict P N/A P



After test the lampholder comply with relevant standard sheets and show no damage

N/A

After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation

N/A

- bending test (N) ................................................... :



After test the lampholder have not moved from its position and show no permanent deformation

N/A

3.6 (4.4.5)

Peak pulse voltage

N/A

3.6 (4.4.6)

Centre contact

N/A

3.6 (4.4.7)

Parts in rough service luminaires resistant to tracking

N/A

3.6 (4.4.8)

Lamp connectors

N/A

3.6 (4.4.9)

Caps and bases correctly used

N/A

3.6 (4.4.10) Light source for lampholder or connection according IEC 60061 not connected another way

N/A

3.6 (4.5)

Starter holders

N/A

Starter holder in luminaires other than class II

N/A

Starter holder class II construction

N/A

3.6 (4.6)

Terminal blocks

P

Tails

N/A

Unsecured blocks

N/A

3.6 (4.7)

Terminals and supply connections

P

3.6 (4.7.1)

Contact to metal parts

P

3.6 (4.7.2)

Test 8 mm live conductor

P

Test 8 mm earth conductor

P

Terminals for supply conductors

P

3.6 (4.7.3)

3.6 (4.7.3.1) Welded method and material TRF No. IEC60598_2_3K

N/A

Page 13 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

- stranded or solid conductor

N/A

- spot welding

N/A

- welding between wires

N/A

- Type Z attachment

N/A

- mechanical test according to 15.8.2

N/A

- electrical test according to 15.9

N/A

- heat test according to 15.9.2.3 and 15.9.2.4

N/A

3.6 (4.7.4)

Terminals other than supply connection

3.6 (4.7.5)

Heat-resistant wiring/sleeves

N/A

3.6 (4.7.6)

Multi-pole plug

N/A

- test at 30 N

N/A

Switches

N/A

- adequate rating

N/A

- adequate fixing

N/A

- polarized supply

N/A

- compliance with IEC 61058-1 for electronic switches

N/A

3.6 (4.9)

Insulating lining and sleeves

N/A

3.6 (4.9.1)

Retainment

N/A

3.6 (4.8)

Method of fixing ...................................................... : 3.6 (4.9.2)

3.6 (4.10)

P



Insulated linings and sleeves:

N/A

Resistant to a temperature > 20 C to the wire temperature or

N/A

a) & c) Insulation resistance and electric strength

N/A

b) Ageing test. Temperature (C) ............................ :

N/A

Double or reinforced insulation

N/A

3.6 (4.10.1) No contact, mounting surface – accessible metal parts – wiring of basic insulation

N/A

Safe installation fixed luminaires

N/A

Capacitors and switches

N/A

Interference suppression capacitors according to IEC 60384-14

N/A

3.6 (4.10.2) Assembly gaps:

N/A

- not coincidental

N/A

- no straight access with test probe

N/A

TRF No. IEC60598_2_3K

Page 14 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

3.6 (4.10.3) Retainment of insulation:

N/A

- fixed

N/A

- unable to be replaced; luminaire inoperative

N/A

- sleeves retained in position

N/A

- lining in lampholder

N/A

1.6 (4.10.4) Protective impedance device

3.6 (4.11)

Verdict

N/A

Double or reinforced insulation bridged by appropriate and at least two resistors or two Y2 capacitors or one Y1 capacitor

N/A

Y1 or Y2 capacitors comply with IEC 60384-14

N/A

Resistors comply with test (a) in 14.1 of IEC 60065

N/A

Electrical connections and current-carrying parts

P

3.6 (4.11.1) Contact pressure

P

3.6 (4.11.2) Screws:

N/A

- self-tapping screws

N/A

- thread-cutting screws

N/A

3.6 (4.11.3) Screw locking:

P

- spring washer

P

- rivets

N/A

3.6 (4.11.4) Material of current-carrying parts

P

3.6 (4.11.5) No contact to wood or mounting surface

P

3.6 (4.11.6) Electro-mechanical contact systems 3.6 (4.12)

N/A

Screws and connections (mechanical) and glands

P

3.6 (4.12.1) Screws not made of soft metal

P

Screws of insulating material

N/A

Torque test: torque (Nm); part................................. :

Screw used in enclosure: 1,2

P

Torque test: torque (Nm); part................................. :

Screw used earthing terminal: 1,2

P

Torque test: torque (Nm); part................................. :

Screw used in spring terminal: 1,2

P

3.6 (4.12.2) Screws with diameter < 3 mm screwed into metal 3.6 (4.12.4) Locked connections:

N/A P

- fixed arms; torque (Nm) ........................................ :

N/A

- lampholder; torque (Nm) ....................................... :

N/A

- push-button switches; torque 0,8 Nm .................... :

N/A

TRF No. IEC60598_2_3K

Page 15 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.6 (4.12.5) Screwed glands; force (Nm).................................... : 3.6 (4.13)

Result - Remark 3,25 Nm

Mechanical strength

P

- fragile parts; energy (Nm) ..................................... :

a) live parts b) linings c) protection d) covers 3.6 (4.13.3) Straight test finger 3.6 (4.13.4) Rough service luminaires

N/A Lens: 0,7;Enclosure: 0,7 CT cap and NEMA cap :0,7

P P N/A P N/A P N/A

- IP54 or higher

N/A

a) fixed

N/A

b) hand-held

N/A

c) delivered with a stand

N/A

d) for temporary installations and suitable for mounting on a stand

N/A

3.6 (4.13.6) Tumbling barrel 3.6 (4.14)

P P

3.6 (4.13.1) Impact tests:

- other parts; energy (Nm)....................................... :

Verdict

Suspensions, fixings and means of adjusting

3.6 (4.14.1) Mechanical load: A) four times the weight

N/A P P P

B) torque 2,5 Nm

N/A

C) bracket arm; bending moment (Nm) ................... :

N/A

D) load track-mounted luminaires

N/A

E) clip-mounted luminaires, glass-shelve. Thickness (mm) ..................................................................... :

N/A

Metal rod. diameter (mm) ....................................... :

N/A

Fixed luminaire or independent control gear without fixing devices

N/A

3.6 (4.14.2) Load to flexible cables

N/A

Mass (kg) .............................................................. :



Stress in conductors (N/mm²) ................................ :

N/A

Mass (kg) of semi-luminaire ................................... :



Bending moment (Nm) of semi-luminaire ............... :

N/A

3.6 (4.14.3) Adjusting devices: TRF No. IEC60598_2_3K

N/A

Page 16 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

- flexing test; number of cycles................................ :

N/A

- strands broken ..................................................... :

N/A

- electric strength test afterwards

N/A

3.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors

N/A

3.6 (4.14.5) Guide pulleys

N/A

3.6 (4.14.6) Strain on socket-outlets

N/A

3.6 (4.15)

Flammable materials - glow-wire test 650C............................................. :

P See Test Table 3.15 (13.3.2)

- spacing 30 mm

N/A

- screen withstanding test of 13.3.1

N/A

- screen dimensions

N/A

- no fiercely burning material

P

- thermal protection

N/A

- electronic circuits exempted

N/A

3.6 (4.15.2) Luminaires made of thermoplastic material with lamp control gear

3.6 (4.16)

N/A

b) temperature sensing control

N/A

c) surface temperature

N/A

Luminaires for mounting on normally flammable surfaces (compliance with Section 12)

3.6 (4.16.1) Lamp control gear spacing:

P N/A N/A

- spacing 35 mm

N/A

- spacing 10 mm

N/A

3.6 (4.16.2) Thermal protection:

N/A

- in lamp control gear

N/A

- external

N/A

- fixed position

N/A

- temperature marked lamp control gear

N/A

3.6 (4.16.3) Design to satisfy the test of 12.6

3.6 (4.18)

N/A

a) construction

No lamp control gear .............................................. :

3.6 (4.17)

P

(see clause 12.6)

N/A

Drain holes

N/A

Clearance at least 5 mm

N/A

Resistance to corrosion

P

3.6 (4.18.1) - rust-resistance

TRF No. IEC60598_2_3K

P

Page 17 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

3.6 (4.18.2) - season cracking in copper

N/A

3.6 (4.18.3) - corrosion of aluminium

N/A

3.6 (4.19)

Igniters compatible with ballast

N/A

3.6 (4.20)

Rough service vibration

N/A

3.6 (4.21)

Protective shield

N/A

3.6 (4.21.1) Shield fitted if tungsten halogen lamps or metal halide lamps

N/A

Shield of glass if tungsten halogen lamps

N/A

3.6 (4.21.2) Particles from a shattering lamp not impair safety

N/A

3.6 (4.21.3) No direct path

N/A

3.6 (4.21.4) Impact test on shield

N/A

Glow-wire test on lamp compartment ...................... :

See Test Table 3.15 (13.3.2)

N/A

3.6 (4.22)

Attachments to lamps not cause overheating or damage

N/A

3.6 (4.23)

Semi-luminaires comply Class II

N/A

3.6 (4.24)

Photobiological hazards

P

3.6 (4.24.1) No excessive UV radiation if tungsten halogen lamps and metal halide lamps (Annex P)

N/A

3.6 (4.24.2) Retinal blue light hazard Class of risk group assessed according to IEC/TR 62778 ................................................................... :

3.6 (4.25)

3.6 (4.26)

P RG1



Luminaires with Ethr :

N/A

a) Fixed luminaires

N/A

- distance x m, borderline between RG1 and RG2... :

N/A

- marking and instruction according 3.2.23

N/A

b) Portable and handheld luminaires

N/A

- marking according 3.2.23 if RG1 exceeded at 200 mm according to IEC/TR 62778

N/A

Portable luminaires for children IEC 60598-2-10 and Mains socket outlet nightlights IEC 60598-2-12 not exceed RG1 at 200 mm according to IEC/62778

N/A

Mechanical hazard

P

No sharp point or edges

P

Short-circuit protection

N/A

3.6 (4.26.1) Adequate means of uninsulated accessible SELV parts

N/A

3.6 (4.26.2) Short-circuit test with test chain according 4.26.3

N/A

TRF No. IEC60598_2_3K

Page 18 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

3.6 (4.27)

3.6 (4.28)

Requirement + Test

Result - Remark

Test chain not melt through

N/A

Test sample not exceed values of Table 12.1 and 12.2

N/A

Terminal blocks with integrated screwless earthing contacts

N/A

Test according Annex V

N/A

Pull test of terminal fixing (20 N)

N/A

After test, resistance < 0,05 

N/A

Pull test of mechanical connection (50 N)

N/A

After test, resistance < 0,05 

N/A

Voltage drop test, resistance < 0,05 

N/A

Fixing of thermal sensing control

N/A

Not plug-in or easily replaceable type

N/A

Reliably kept in position

N/A

No adhesive fixing if UV radiations from a lamp can degrade the fixing

N/A

Not outside the luminaire enclosure

N/A

Test of adhesive fixing:

N/A

Max. temperature on adhesive material (C) ........... :

3.6 (4.29)

3.6 (4.30)

3.6 (4.31)

Verdict



100 cycles between t min and t max

N/A

Temperature sensing control still in position

N/A

Luminaires with non-replaceable light source

P

Not possible to replace light source

P

Live part not accessible after parts have been opened by hand or tools

N/A

Luminaires with non-user replaceable light source

N/A

If protective cover provide protection against electric shock and marked with “caution, electric shock risk” symbol:

N/A

Minimum two fixing means

N/A

Insulation between circuits

P

Circuits insulated from LV supply fulfil requirements according 4.31.1 – 4.31.3

P

Controllable luminaires requiring same level of insulation for all components, the insulation between control terminals and LV supply fulfil requirements according 4.31.1 – 4.31.3

N/A

3.6 (4.31.1) SELV circuits Used SELV source TRF No. IEC60598_2_3K

N/A N/A

Page 19 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

Voltage ≤ ELV

N/A

Insulating of SELV circuits from LV supply

N/A

Insulating of SELV circuits from other non SELV circuits

N/A

Insulating of SELV circuits from FELV

N/A

Insulating of SELV circuits from other SELV circuits

N/A

SELV circuits insulated from accessible parts according Table X.1

N/A

Plugs not able to enter socket-outlets of other voltage systems

N/A

Socket outlets does not admit plugs of other voltage systems

N/A

Plugs and socket-outlets does not have protective conductor contact

N/A

3.6 (4.31.2) FELV circuits

N/A

Used FELV source

N/A

Voltage ≤ ELV

N/A

Insulating of FELV circuits from LV supply

N/A

FELV circuits insulated from accessible parts according Table X.1

N/A

Plugs not able to enter socket-outlets of other voltage systems

N/A

Socket outlets does not admit plugs of other voltage systems

N/A

Socket-outlets does not have protective conductor contact

N/A

3.6 (4.31.3) Other circuits Other circuits insulated from accessible parts according Table X.1

P P

Class II construction with equipotential bonding for protection against indirect contacts with live parts:

N/A

- conductive parts are connected together

N/A

- test according 7.2.3 of above

N/A

- conductive part not cause an electric shock in case of an insulation fault

N/A

- equipotential bonding in master/slave applications

N/A

- master luminaire provided with terminal for accessible conductive parts of slave luminaires

N/A

- slave luminaire constructed as class I

N/A

TRF No. IEC60598_2_3K

Page 20 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.6 (4.32)

Overvoltage protective devices

P

Comply with IEC 61643-11

P

External to controlgear and connected to earth:

P

- only in fixed luminaires

P

- only connected to protective earth

P

3.6.1 (-)

At least IP X3 or X5 respectively. IP ................... :

Result - Remark

IP66

Verdict

P

Column-integrated luminaires:

N/A

- parts below 2,5 m. IP ....................................... :

N/A

- parts above 2,5 m. IP ...................................... :

N/A

3.6.2 (-)

Suspension on span wires

N/A

3.6.3 (-)

Means for attaching the luminaire or external parts to its support appropriate to the weight

P

3.6.3.1 (-)

Static load test

P

- drag coefficient ................................................. :

1,2

P

- loaded area (m²)............................................... :

0,25 for BRP394 LED384/NW 320W 220-240V DM 0,1 for BRP391 LED60/NW 50W 220-240V DM 0,14 for BRP392 LED192/NW 160W 220-240V DM

P

496,86 for BRP394 LED384/NW 320W 220-240V DM 165,6 for BRP391 LED60/NW 50W 220-240V DM 31,9 for BRP392 LED192/NW 160W 220-240V DM

P

0

P

- used load (N).................................................... :

- measured deformation (cm/m) ......................... : - no rotation

P

3.6.4 (-)

Adjustable lampholders

N/A

3.6.5 (-)

Luminaires installed above 5 m, glass covers shall be:

N/A

a) glass that fractures into small pieces (test according to 3.6.5.1), or

N/A

b) glass having a high impact shock resistance (test according to 3.6.5.2), or

N/A

c) protected by any means to retain glass fragments

N/A

For tunnel luminaires 3.6.5.1 apply

N/A

Method of protection declared by the manufacturer

N/A

TRF No. IEC60598_2_3K

Page 21 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.6.5.1 (-)

Protection by the use of glass that fractures into small pieces

N/A

- number of particles is more than 40 .................. :

N/A

Protection by the use of high impact resistant glass

N/A

3.6.5.2 (-)

Result - Remark

3.6.5.2.1 (-) Glass covers have high mechanical strength

Verdict

N/A N/A

Test according IEC 62262 with test apparatus according IEC 60068-2-75 with impact energy of 5J on preconditioned sample 3.6.5.2.2 (-) Glass covers not break into large pieces

N/A

- test according 3.6.5.1, number of particles is more than 20 ............................................................... :

N/A

Connection compartment of column-integrated luminaire

N/A

- provides adequate space

N/A

- means for attachment

N/A

- means for attachment of metal corrosion-resistant

N/A

3.6.7 (-)

Compliance with ISO standard or other............... :

N/A

3.6.8 (-)

Doors of column-integrated luminaires:

N/A

- corrosion-resistant

N/A

- opening only possible for an authorized person

N/A

- impact test 5 Nm

N/A

- sample show no damage

N/A

Column-integrated luminaire:

N/A

- dimension of the cable entry slot (mm).............. :

N/A

- cable path from the slot to the connection compartment (mm) ............................................ :

N/A

- cable path free from obstruction that might cause abrasion of the cable

N/A

3.6.6 (-)

3.6.9 (-)

3.7 (11)

CREEPAGE DISTANCES AND CLEARANCES

3.7 (11.2)

Creepage distances and clearances ....................... :

See Table 3.7 (11.2)

P

Impulse withstand category (Normal category II) (Category III Annex U, Table U.1)

Category II



P

Category III

3.8 (7)

PROVISION FOR EARTHING

P

3.8 (7.2.1 + 7.2.3)

Accessible metal parts

P

Metal parts in contact with supporting surface

P

Resistance < 0,5  ................................................. : TRF No. IEC60598_2_3K

0,046

P

Page 22 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Self-tapping screws used

Verdict P

Thread-forming screws

N/A

Thread-forming screw used in a grove

N/A

Earth makes contact first

N/A

Terminal blocks with integrated screwless earthing contacts tested according Annex V

N/A

Protective earthing of the luminaire not via built-in control gear

P

3.8 (7.2.2 + 7.2.3)

Earth continuity in joints, etc.

N/A

3.8 (7.2.4)

Locking of clamping means

P

Compliance with 4.7.3

P

Terminal blocks with integrated screwless earthing contacts tested according Annex V

N/A

3.8 (7.2.5)

Earth terminal integral part of connector socket

N/A

3.8 (7.2.6)

Earth terminal adjacent to mains terminals

P

3.8 (7.2.7)

Electrolytic corrosion of the earth terminal

P

3.8 (7.2.8)

Material of earth terminal

P

Contact surface bare metal

P

3.8 (7.2.10) Class II luminaire for looping-in

N/A

Double or reinforced insulation to functional earth

N/A

3.8 (7.2.11) Earthing core coloured green-yellow

N/A

Length of earth conductor

N/A

3.8.1 (-)

Attachment prevented from rotation

N/A

3.9 (14)

SCREW TERMINALS

3.9 (15)

P

Separately approved; component list ...................... :

(see Annex 1)

P

Part of the luminaire ............................................... :

(see Annex 3)

N/A

SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS

P

Separately approved; component list ...................... :

(see Annex 1)

N/A

Part of the luminaire ............................................... :

(see Annex 4)

P

3.10 (5)

EXTERNAL AND INTERNAL WIRING

P

3.10 (5.2)

Supply connection and external wiring

P

3.10 (5.2.1) Means of connection............................................... : TRF No. IEC60598_2_3K

Terminal block

P

Page 23 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

Outdoor luminaire has not PVC insulated external wiring if not class III or SELV ≤ 25 V a.c./60 V d.c. or protected from outdoor environment

N/A

3.10 (5.2.2) Type of cable.......................................................... :

N/A

Nominal cross-sectional area (mm²)........................ :

N/A

Cables equal to IEC 60227 or IEC 60245

N/A

3.10 (5.2.3) Type of attachment, X, Y or Z

N/A

3.10 (5.2.5) Type Z not connected to screws

N/A

3.10 (5.2.6) Cable entries:

P

- suitable for introduction

P

- adequate degree of protection

P

3.10 (5.2.7) Cable entries through rigid material have rounded edges 3.10 (5.2.8) Insulating bushings:

P N/A

- suitably fixed

N/A

- material in bushings

N/A

- material not likely to deteriorate

N/A

- tubes or guards made of insulating material

N/A

3.10 (5.2.9) Locking of screwed bushings

N/A

Cord anchorage:

P

- covering protected from abrasion

P

- clear how to be effective

P

- no mechanical or thermal stress

P

- no tying of cables into knots etc.

P

- insulating material or lining

P

3.10 (5.2.10)

3.10 (5.2.10.1)

Cord anchorage for type X attachment:

N/A

a) at least one part fixed

N/A

b) types of cable

N/A

c) no damaging of the cable

N/A

d) whole cable can be mounted

N/A

e) no touching of clamping screws

N/A

f) metal screw not directly on cable

N/A

g) replacement without special tool

N/A

Glands not used as anchorage

N/A

TRF No. IEC60598_2_3K

Page 24 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

Labyrinth type anchorages

N/A

3.10 (5.2.10.2)

Adequate cord anchorage for type Y and type Z attachment

N/A

3.10 (5.2.10.3)

Tests:

P

- impossible to push cable; unsafe

P

- pull test: 25 times; pull (N) .................................... :

80 N

P

- torque test: torque (Nm)........................................ :

0,35 Nm

P

- displacement  2 mm

P

- no movement of conductors

P

- no damage of cable or cord

P

- function independent of electrical connection

P

3.10 (5.2.11)

External wiring passing into luminaire

N/A

3.10 (5.2.12)

Looping-in terminals

N/A

3.10 (5.2.13)

Wire ends not tinned

N/A

Wire ends tinned: no cold flow

N/A

Mains plug same protection

N/A

Class III luminaire plug

N/A

No unsafe compatibility

N/A

Appliance inlets (IEC 60320)

N/A

Installation couplers (IEC 61535)

N/A

Other appliance inlet or connector according relevant IEC standard

N/A

3.10 (5.2.17)

No standardized interconnecting cables properly assembled

N/A

3.10 (5.2.18)

Used plug in accordance with

N/A

- IEC 60083

N/A

- other standard

N/A

Internal wiring

P

3.10 (5.2.14)

3.10 (5.2.16)

3.10 (5.3)

3.10 (5.3.1) Internal wiring of suitable size and type

P

Through wiring

N/A

- not delivered/ mounting instruction

N/A

TRF No. IEC60598_2_3K

Page 25 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

N/A

- socket outlet loaded (A) ........................................ :

N/A (see Annex 2)

P

Green-yellow for earth only

P

Internal wiring connected directly to fixed wiring

P

Cross-sectional area (mm²) .................................... :

See annex 1

Insulation thickness Extra insulation added where necessary 3.10 (5.3.1.2)

Verdict

- factory assembled

- temperatures ........................................................ :

3.10 (5.3.1.1)

Result - Remark

Internal wiring connected to fixed wiring via internal current-limiting device

P P N/A P

Adequate cross-sectional area and insulation thickness

N/A

3.10 (5.3.1.3)

Double or reinforced insulation for class II

N/A

3.10 (5.3.1.4)

Conductors without insulation

N/A

3.10 (5.3.1.5)

SELV current-carrying parts

N/A

3.10 (5.3.1.6)

Insulation thickness other than PVC or rubber

N/A

3.10 (5.3.2) Sharp edges etc.

P

No moving parts of switches etc.

N/A

Joints, raising/lowering devices

N/A

Telescopic tubes etc.

N/A

No twisting over 360

N/A

3.10 (5.3.3) Insulating bushings:

N/A

- suitable fixed

N/A

- material in bushings

N/A

- material not likely to deteriorate

N/A

- cables with protective sheath

N/A

3.10 (5.3.4) Joints and junctions effectively insulated

N/A

3.10 (5.3.5) Strain on internal wiring

N/A

3.10 (5.3.6) Wire carriers

N/A

3.10 (5.3.7) Wire ends not tinned Wire ends tinned: no cold flow 3.10.1 (-)

Cord anchorage if applicable

TRF No. IEC60598_2_3K

P N/A P

Page 26 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

3.11 (8)

Requirement + Test

Result - Remark

- pull test: 25 times; pull (N) ................................ :

60

P

- torque test: torque (Nm).................................... :

0,25

P

PROTECTION AGAINST ELECTRIC SHOCK

3.11 (8.2.1) Live parts not accessible

Verdict

P P

Basic insulated parts not used on the outer surface without appropriate protection

P

Basic insulated parts not accessible with standard test finger on portable, settable and adjustable luminaires

N/A

Basic insulated parts not accessible with Ø 50 mm probe from outside, other types of luminaires

N/A

Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements

N/A

Basic insulation only accessible under lamp or starter replacement

N/A

Protection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable

P N/A P

Double-ended high pressure discharge lamp

N/A

Relevant warning according to 3.2.18 fitted to the luminaire

N/A

3.11 (8.2.2) Portable luminaire adjusted in most unfavourable position

N/A

Class II luminaire:

N/A

- basic insulated metal parts not accessible during starter or lamp replacement

N/A

- basic insulation not accessible other than during starter or lamp replacement

N/A

- glass protective shields not used as supplementary insulation

N/A

3.11 (8.2.3.b)

BC lampholder of metal in class I luminaires shall be earthed

N/A

3.11 (8.2.3.c)

SELV circuits with exposed current carrying parts:

N/A

Ordinary luminaire:

N/A

- voltage under load (V) .......................................... :

N/A

3.11 (8.2.3.a)

TRF No. IEC60598_2_3K

Page 27 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

- no-load voltage (V) ........................................... :

N/A

- touch current if applicable (mA) ....................... :

N/A

One conductive part insulated if required

N/A

Other than ordinary luminaire:

N/A

- nominal voltage (V) .............................................. :

N/A

Class III luminaire only for connection to SELV

N/A

Class III luminaire not provided with means for protective earthing

N/A

3.11 (8.2.4) Portable luminaire have protection independent of supporting surface

N/A

3.11 (8.2.5) Compliance with the standard test finger or relevant probe

P

3.11 (8.2.6) Covers reliably secured

P

3.11 (8.2.7) Discharging of capacitors  0,5 F

P

Portable plug connected luminaire with capacitor

N/A

Other plug connected luminaire with capacitor

N/A

Discharge device on or within capacitor

N/A

Discharge device mounted separately

N/A

3.12 (12)

ENDURANCE TEST AND THERMAL TEST

P

3.12.2 (-)

If IP > IP 20 relevant test of (12.4), (12.5) and (12.6) after (9.2) before (9.3) specified in 3.13



3.12 (12.3)

Endurance test:

P

3.12 (12.3.2)

- mounting-position ................................................. :

Normal mounting position



- test temperature (C) ............................................ :

45



- total duration (h) ................................................... :

240 h



- supply voltage: Un factor; calculated voltage (V) ... :

240 x 1,1



- lamp used ............................................................ :

LED module as delivered



After endurance test:

P

- no part unserviceable

P

- luminaire not unsafe

P

- no damage to track system

N/A

- marking legible

P

- no cracks, deformation etc.

P

TRF No. IEC60598_2_3K

Page 28 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

3.12 (12.4)

Thermal test (normal operation)

(see Annex 2)

P

3.12 (12.5)

Thermal test (abnormal operation)

(see Annex 2)

N/A

3.12 (12.6)

Thermal test (failed lamp control gear condition):

3.12 (12.6.1)

Through wiring or looping-in wiring loaded by a current of (A) ......................................................... :



- case of abnormal conditions ................................. :



- electronic lamp control gear

3.12 (12.6.2)

Verdict

N/A

N/A

- measured winding temperature (C): at 1,1 Un .... :



- measured mounting surface temperature (C) at 1,1 Un .................................................................... :

N/A

- calculated mounting surface temperature (C) ..... :

N/A

- track-mounted luminaires

N/A

Temperature sensing control

N/A

- case of abnormal conditions ................................. :



- thermal link

N/A

- manual reset cut-out

N/A

- auto reset cut-out

N/A

- measured mounting surface temperature (C)....... :

N/A

- track-mounted luminaires

N/A

3.12 (12.7)

Thermal test (failed lamp control gear in plastic luminaires):

N/A

3.12 (12.7.1)

Luminaire without temperature sensing control

N/A

3.12 (12.7.1.1)

Luminaire with fluorescent lamp ≤ 70W

N/A

Test method 12.7.1.1 or Annex W .......................... : Test according to 12.7.1.1:

 N/A

- case of abnormal conditions ................................. :



- Ballast failure at supply voltage (V) ...................... :



- Components retained in place after the test

N/A

- Test with standard test finger after the test

N/A

Test according to Annex W:

N/A

- case of abnormal conditions ................................. :



- measured winding temperature (C): at 1,1 Un ..... :



- measured temperature of fixing point/exposed part (C): at 1,1 Un ........................................................ :



TRF No. IEC60598_2_3K

Page 29 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark



- calculated temperature of fixing point/exposed part (C) ........................................................................ : Ball-pressure test................................................ : 3.12 (12.7.1.2)

See Table 3.15 (13.2.1)

Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA

N/A 

- measured winding temperature (C): at 1,1 Un ..... :



- measured temperature of fixing point/exposed part (C): at 1,1 Un ........................................................ :



- calculated temperature of fixing point/exposed part (C) ........................................................................ :

 See Table 3.15 (13.2.1)

N/A N/A

Luminaire with short circuit proof transformers ≤ 10 VA



- case of abnormal conditions ................................. :

3.12 (12.7.2)

N/A

- case of abnormal conditions ................................. :

Ball-pressure test.................................................... : 3.12 (12.7.1.3)

Verdict

- Components retained in place after the test

N/A

- Test with standard test finger after the test

N/A

Luminaire with temperature sensing control

N/A

- thermal link........................................................... :

Yes

No



- manual reset cut-out ............................................. :

Yes

No



- auto reset cut-out ................................................. :

Yes

No



- case of abnormal conditions ................................. :



- highest measured temperature of fixing point/ exposed part (C): .................................................. :



Ball-pressure test:................................................... :

See Table 3.15 (13.2.1)

N/A

3.12.1 (-)

Temperature reduction if for outdoor use only

P

3.12.2 (-)

(See above)



3.12.3 (-)

Glass covers used within the thermal limits declared by the glass manufacturer

3.13 (9)

RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE

P

3.13.1 (-)

If IP > IP 20 the order of tests as specified in clause 3.12

P

3.13 (9.2)

Tests for ingress of dust, solid objects and moisture:



N/A

- classification according to IP................................. :

IP66



- mounting position during test ................................ :

Normal mounting position



TRF No. IEC60598_2_3K

Page 30 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

- fixing screws tightened; torque (Nm) ..................... :

Gland: 3,25 x 2/3 Screw: 1,2 x 2/3



- tests according to clauses .................................... :

9.2.2 & 9.2.7



- electric strength test afterwards

P

a) no deposit in dust-proof luminaire

N/A

b) no talcum in dust-tight luminaire

P

c) no trace of water on current-carrying parts or on insulation where it could become a hazard

P

c.1) For luminaires without drain holes – no water entry

P

c.2) For luminaires with drain holes – no hazardous water entry

N/A

d) no water in watertight luminaire

N/A

e) no contact with live parts (IP 2X)

N/A

e) no entry into enclosure (IP 3X and IP 4X)

N/A

e) no contact with live parts (IP3X and IP4X)

N/A

f) no trace of water on part of lamp requiring protection from splashing water

N/A

g) no damage of protective shield or glass envelope

N/A

3.13 (9.3)

Humidity test 48 h

P

3.14 (10)

INSULATION RESISTANCE AND ELECTRIC STRENGTH

P

3.14 (10.2.1)

Insulation resistance test

P

Cable or cord covered by metal foil or replaced by a metal rod of mm Ø ................................................. :

--



Insulation resistance (M) ...................................... :

500 M



SELV

N/A

- between current-carrying parts of different polarity :

N/A

- between current-carrying parts and mounting surface ................................................................... :

N/A

- between current-carrying parts and metal parts of the luminaire........................................................... :

N/A

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ...... :

N/A

TRF No. IEC60598_2_3K

Page 31 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Other than SELV

P

- between live parts of different polarity ................... :

3.14 (10.2.2)

N/A

- between live parts and mounting surface .............. :

500 M

P

- between live parts and metal parts........................ :

500 M

P

- between live parts of different polarity through action of a switch .................................................... :

N/A

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ......:

N/A

Electric strength test

P

Dummy lamp

N/A

Luminaires with ignitors after 24 h test

N/A

Luminaires with manual ignitors

N/A

Test voltage (V) ...................................................... :

1680

P

SELV

N/A

- between current-carrying parts of different polarity :

N/A

- between current-carrying parts and mounting surface ................................................................... :

N/A

- between current-carrying parts and metal parts of the luminaire........................................................... :

N/A

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ...... :

N/A

Other than SELV

P

- between live parts of different polarity ................... :

3.14 (10.3)

Verdict

N/A

- between live parts and mounting surface .............. :

1680 V

P

- between live parts and metal parts........................ :

1680 V

P

- between live parts of different polarity through action of a switch .................................................... :

N/A

- between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ...... :

N/A

Touch current or protective conductor current (mA). :

TRF No. IEC60598_2_3K

Protective conduct current 0,04 < 3,5

P

Page 32 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

3.15 (13)

RESISTANCE TO HEAT, FIRE AND TRACKING

3.15 (13.2.1)

Ball-pressure test....................................................:

See Test Table 3.15 (13.2.1)

P

3.15 (13.3.1)

Needle-flame test (10 s) .........................................:

See Test Table 3.15 (13.3.1)

P

3.15 (13.3.2)

Glow-wire test (650C)............................................:

See Test Table 3.15 (13.3.2)

P

3.15 (13.4)

Proof tracking test (IEC 60112) ...............................:

See Test Table 3.15 (13.4)

3.7 (11.2)

TABLE: Creepage distances and clearances

P

Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages

P

Applicable part of IEC 60598-1 Table 11.1* and 11.2*

P

Distance 1:

Insulation type **

Measured clearance

B

4,5

Result - Remark

P

Required clearance

*Table

2,2

11.1

Verdict

Measured creepage 4,5

Working voltage (V) ................................................................... :

340

PTI ............................................................................................ :

< 600

Pulse voltage if applicable (kV) ................................................. :

--

N/A

Required creepage

*Table

3,4

11.1 

> 600

 

Supplementary information: live part on LED module to accessible part Distance 2: 

Working voltage (V) ................................................................... : PTI ............................................................................................ :

< 600

> 600

 

Pulse voltage if applicable (kV) ................................................. : Supplementary information: Distance 3:



Working voltage (V) ................................................................... : PTI ............................................................................................ : Pulse voltage if applicable (kV) ................................................. : Supplementary information:

TRF No. IEC60598_2_3K

< 600

> 600

 

Page 33 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

3.15 (13.2.1)

TABLE: Ball Pressure Test of Thermoplastics

Verdict

P 

Allowed impression diameter (mm) ................... :

2,0

Object/ Part No./ Material

Manufacturer/ trademark

Test temperature (C)

Impression diameter (mm)

Screwless terminal on LED module

--

125

0,9

Lens

--

125

0,9

Socket

--

125

0,9

Supplementary information:

3.15 (13.3.1)

P

TABLE: Needle-flame test (IEC 60695-11-5)

Object/ Part No./ Material

Manufacturer/ trademark

Connector

--

Socket

--

Duration of application of test flame (ta); (s)

Ignition of specified layer Yes/No

Duration of burning (tb) (s)

Verdict

10

No

0

P

10

No

0

P

Supplementary information:

3.15 (13.3.2)

P

TABLE: Glow-wire test (IEC 60695-2-11)

Glow wire temperature ........................................ : Object/ Part No./ Material

Manufacturer/ trademark

Insulation sleeve

--

Gasket



650°C Ignition of specified layer Yes/No

Duration of burning (tb) (s)

Verdict

30

No

0

P

--

30

No

0

P

Gland

--

30

No

0

P

Rubber in gland

--

30

No

0

P

Lens

--

30

No

0

P

Paper on LED driver

--

30

No

0

P

Socket

--

30

No

0

P

TRF No. IEC60598_2_3K

Duration of application of test flame (ta); (s)

Page 34 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, and any burning or molten drop did not ignite the underlying parts (Yes/No) ..................................... :

Verdict Yes

Supplementary information:

3.15 (13.4)

TABLE: Proof tracking test (IEC 60112)

Test voltage PTI .................................................. :

175 V

Object/ Part No./ Material

Withstand 50 drops without failure on three places or on three specimens

Supplementary information:

TRF No. IEC60598_2_3K

Manufacturer/ trademark

N/A  Verdict

Page 35 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

ANNEX 1

TABLE: Critical components information

Object / part No.

Code

Manufacturer/ trademark

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

TRF No. IEC60598_2_3K

Result - Remark

Verdict P Mark(s) of conformity1)

Type / model Technical data

Standard

Input: 120 - 277 V~; 50 / 60 Hz; tc = Xitanium 40W 80 ℃; 0.70A Prog+ Output: GL-J sXt Iout = 100~700 mA; Uout = 29 57 Vdc; Input: 220Xitanium 50W 240V~ 50/60Hz 0.70A 230V-J output 0.7A; cXt Uout: 35-71 Vdc 50W; tc: 80℃ tc:80℃, Vin(V):220-240; Xitanium Iin(A):0.52-0.48; 100W 0.7A Freq(Hz):50/60; 230V Y PF:0.95; Vout(V):64-143; Iout(mA):700 Input: 220 - 240 VAC; 50 / 60 Hz; Xitanium Tc = 80 ℃; 150W 0.7A output = 700 mA; 230V Y 96-214 Vdc; Uout: 320V Input: 220-240V~ 50/60Hz Xi LP 75W Output: 0.2-0.7A S1 0.2-0.7A; 50230V S240 150Vdc sXt Max.190Vdc, 75W; tc: 85℃ Input: 220240V~ 50/60Hz Xi LP 150W 0.2-0.7A S1 output 0.2-0.7A; 230V S240 90-283 Vdc tc: sXt 85℃, Uout: 340V

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

Page 36 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

PHILIPS

LED driver

B

Terminal block

B

TRF No. IEC60598_2_3K

Result - Remark

Verdict

Input: 220-240V~ Xi FP 75W 0 50/60Hz 2-0 7A Output: SNLDAE 0.2-0.7A; 230V S240 50-150Vdc, sXt Max.190Vdc, 75W; tc: 85℃" Xi FP 150W 0 Input: 2-0 7A 220-240V~ SNLDAE 50/60Hz 230V S240 Output: sXt 0.2-0.7A; 90-283Vdc, Max.340Vdc, 150W; tc: 90℃" Xitanium 75W Input: 1200.35-0.7A GL 277V~ 50/60Hz Prog sXt output 0.35-0.7A; 80 - 152 Vdc tc: 80℃, Uout: 160V Xitanium Input: 120150W 0.35277V~ 50/60Hz 0.7A GL Prog output 0.35-0.7A; sXt 125 - 280 Vdc tc: 80℃, Uout: 296V

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

Xi SR 150W 0.2-0.7A SNEMP 230V S240 sXt

IEC 61347-213

DEKRA CB

IEC 61347-213

DEKRA CB

IEC 60998

CQC

Input: 220-240V, 50/60Hz, 0.760.72A, 162W, PF: 0.95; Output: 90283VDC, 0.200.70A, 150W, tc: 90C, Uout max=340V PHILIPS Xi SR 75W Input: 220-240V, 0.2-0.7A 50/60Hz, 0.38SNEMP 230V 0.34A, 82W, PF: S240 sXt 0.95; Output: 50150VDC, 0.200.70A, 75W, tc: 80C, Uout max=200V Yuyao City Lixun PA12,PA10,P 500V, Electronics Co., A8 0,5~2,5 mm² Ltd. 110℃

Page 37 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Terminal block

B

Jingbi electric (dongwan)

PA8DS, PA10DS

Internal wire

C

Shanghai Charles

XM-1452-18 or 1316-18

Internal wire

C

AGR,AG

Internal wire

C

Internal wire

C

Earthing wrie

C

Earthing wrie

C

Nipple cap

C

Screwless terminal on LED module LED module

C

Shanghai SECRI Special Cable Co., Ltd Shanghai minglan Shanghai minglan Shanghai minglan Shanghai Shunqiao Jingbi electric (dongwan) TE

C

PHILIPS

SPD (between terminal block and LED driver)

B

PHILIPS

SPD (between terminal block and LED driver)

B

PHILIPS

SPD (between LED driver and LED module)

C

PHILIPS

TRF No. IEC60598_2_3K

AGR,AG AGR,AG FF46-1 19/0.23 60227 IEC 05(BV) CE1,CE2 2106431-1

PA10DS 2,5 mm2 450V T110, PA8DS 1,5 mm2 450V T110 18AWG 105℃ (AWM 1316), 600V(AWM 1316) 0,75 mm2 ; 200℃,

IEC 60998

CQC

IEC 60598-23

Tested in appliance

IEC 60598-23

Tested in appliance

0,75 mm2 ; 200℃, 0.5-0.75 mm2 200℃,300/500V 0.75 mm2 200℃,600V 1 mm2 200℃,300/500V --

IEC 60598-23 IEC 60598-23 IEC 60598-23 IEC 60598-23 IEC 60695

500V/5A~ 700 mA 0,75 mm2 Ledgine board 200-1000 mA SPD G3 15kV/15kA

Verdict

Tested in appliance Tested in appliance Tested in appliance Tested in appliance CQC1313409 3094 IEC 60598-1 DEKRA report 3184212.50Q S IEC 62031 Tested in appliance IEC 61643-11 DEKRA CB

Test class II / Type 2 & Test class III / Type 3, IP20 UC = 242 V~, In = 5 kA, Imax = 15 kA, UOC = 15 kV SPD G3 10kV Test class III / IEC 61643-11 DEKRA CB Type 3, IP20 UC = 242 V~, UOC = 10 kV Surge protect Uc: 100 V; Up: IEC 61347-2- Tested in device 2.0 700 V; fn: DC; In: 11 appliance output 650 A; Imax: 1,2 kA

Page 38 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

7 pin NEMA PE cell socket

C

PHILIPS

2213362-4

CityTouch controller

B

PHILIPS

LLC7280

Surge protect device 2.0 output Terminal block B Shenzhen HYT-230 Hongyu Electrical Co., Ltd Y capacitor B MURATA -Enclosure

C

PHILIPS

--

PCB

C

PHILIPS

--

Power contacts :Current rating:15 A max Voltage rating: 480 VAC/DC Dimming contacts: Current rating 0.10 A max Voltage rating: 10 VAC/DC UL (E66375) 15V/24VDC; 100-480VAC, 50/60Hz; Power <0.5W;

Verdict

IEC 60598-23

Tested in appliance

EN 61347-211

ENEC 05

230 V; 0,75 – 1,5 IEC 60998-2mm2 1

VDE

10000 pF; 250 V; IEC 60384-14 Y2 PBT IEC 61347-211 V-0 IEC 61347-211

VDE Tested in appliance Tested in appliance

Supplementary information: 1) Provided evidence ensures the agreed level of compliance. See OD-CB2039. The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D - Alternative component

TRF No. IEC60598_2_3K

Page 39 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

ANNEX 2

Result - Remark

Verdict

TABLE: Temperature measurements, thermal tests of Section 12

P

Type reference .................................................... : BRP394 LED384/NW 320W 220-240V DM



Lamp used .......................................................... : LED module as delivered



Lamp control gear used ....................................... : Xitanium 150W 0.7A 230V Y



Mounting position of luminaire.............................. : Normal mounting position



Supply wattage (W) ............................................. : 327 Supply current (A) ............................................... : 1,3 Calculated power factor ....................................... : 0,9 Table: measured temperatures corrected for ta =35 C: - abnormal operating mode .................................. : The LED driver will shut down under output short-circuited - test 1: rated voltage ........................................... : -- test 2: 1,06 times rated voltage or 1,05 times 240 rated wattage ...................................................... : - test 3: Load on wiring to socket-outlet, 1,06 times 254,4 voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated -wattage ............................................................... : Through wiring or looping-in wiring loaded by a -current of A during the test .................................. : Temperature measurements, (C)

  

Clause 12.4 – normal Part

Ambient

test 1

test 2

P      

Clause 12.5 – abnormal

test 3

limit

test 4

limit

PCB for LED module

--

--

61,3

--

130

--

--

Screwless terminal

--

--

58,3

--

90

--

--

--

73,5

--

200

--

--

Internal wire Reflector

--

--

73,5

--

Ref.

--

--

Gasket

--

--

50,7

--

90

--

--

tc

--

69,7

--

--

80

--

--

Nipple cap

--

--

63,5

--

90

--

--

Earthing wire

--

--

56,5

--

200

--

--

Gland

--

--

43,1

--

90

--

--

SPD

--

--

45,5

--

90

--

--

TRF No. IEC60598_2_3K

Page 40 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

Sleeve

--

--

42,5

--

90

--

--

Supply cord

--

--

48,7

--

75

--

--

Terminal block

--

--

47,7

--

110

--

--

Lens

--

--

70,4,

--

90

--

--

Mounting surface

--

--

47,7

--

90

--

--

Supplementary information: 10 C has deducted from measured value

ANNEX 2

TABLE: Temperature measurements, thermal tests of Section 12

P

Type reference .................................................... : BRP394 LED384/NW 320W 220-240V DM



Lamp used .......................................................... : LED module as delivered



Lamp control gear used ....................................... : Xi FP 150W 0.2-0.7A SNLDAE 230V S240 sXt 7 pin NEMA socket



Mounting position of luminaire.............................. : Normal mounting position



Supply wattage (W) ............................................. : 327 Supply current (A) ............................................... : 1,3 Calculated power factor ....................................... : 0,9 Table: measured temperatures corrected for ta =35 C: - abnormal operating mode .................................. : The LED driver will shut down under output short-circuited - test 1: rated voltage ........................................... : -- test 2: 1,06 times rated voltage or 1,05 times 240 rated wattage ...................................................... : - test 3: Load on wiring to socket-outlet, 1,06 times 254,4 voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated -wattage ............................................................... : Through wiring or looping-in wiring loaded by a -current of A during the test .................................. : Temperature measurements, (C)

  

Clause 12.4 – normal Part

Ambient

Socket Internal wire

--

test 1

     

Clause 12.5 – abnormal

test 3

limit

test 4

limit

--

37,3

--

90

--

--

--

73,5

--

200

--

--

Supplementary information: 10 C has deducted from measured value

TRF No. IEC60598_2_3K

test 2

P

Page 41 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

ANNEX 2

Result - Remark

Verdict

TABLE: Temperature measurements, thermal tests of Section 12

P

Type reference .................................................... : BRP392 LED192/NW 160W 220-240V DM



Lamp used .......................................................... : LED module as delivered



Lamp control gear used ....................................... : Xi FP 150W 0.2-0.7A SNLDAE 230V S240 sXt



Mounting position of luminaire.............................. : Normal mounting position



Supply wattage (W) ............................................. : 162,9 Supply current (A) ............................................... : 0,689 Calculated power factor ....................................... : 0,985 Table: measured temperatures corrected for ta =35 C: - abnormal operating mode .................................. : The LED driver will shut down under output short-circuited - test 1: rated voltage ........................................... : -- test 2: 1,06 times rated voltage or 1,05 times 240 rated wattage ...................................................... : - test 3: Load on wiring to socket-outlet, 1,06 times 254,4 voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated -wattage ............................................................... : Through wiring or looping-in wiring loaded by a -current of A during the test .................................. : Temperature measurements, (C)

  

Clause 12.4 – normal Part

Ambient

P      

Clause 12.5 – abnormal

test 1

test 2

test 3

limit

test 4

limit

tc

--

81

--

--

90

--

--

Terminal block

--

--

59,3

--

110

--

--

--

56,5

--

110

--

--

Nipple cap Internal wire

--

--

59,8

--

200

--

--

Earthing wire

--

--

55,4

--

200

--

--

Supplementary information: 10 C has deducted from measured value

TRF No. IEC60598_2_3K

Page 42 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

ANNEX 2

TABLE: Temperature measurements, thermal tests of Section 12

Verdict

P

Type reference .................................................... : BRP391 LED60/NW 50W 220240V



Lamp used .......................................................... : LED module as delivered



Lamp control gear used ....................................... : Xitanium 50W 0.70A 230V-J cXt  Mounting position of luminaire.............................. : Normal mounting position



Supply wattage (W) ............................................. : 49,9 Supply current (A) ............................................... : 0,217 Calculated power factor ....................................... : 0,96 Table: measured temperatures corrected for ta =35 C: - abnormal operating mode .................................. : The LED driver will shut down under output short-circuited - test 1: rated voltage ........................................... : -- test 2: 1,06 times rated voltage or 1,05 times 240 rated wattage ...................................................... : - test 3: Load on wiring to socket-outlet, 1,06 times 254,4 voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated -wattage ............................................................... : Through wiring or looping-in wiring loaded by a -current of A during the test .................................. : Temperature measurements, (C)

  

Clause 12.4 – normal Part

Ambient

tc

--

test 1 62,8

Supplementary information: 10 C has deducted from measured value

TRF No. IEC60598_2_3K

P      

Clause 12.5 – abnormal

test 2

test 3

--

--

limit 80

test 4

limit --

--

Page 43 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause ANNEX 2

Requirement + Test

Result - Remark

Verdict

TABLE: Temperature measurements, thermal tests of Section 12

P

Type reference .................................................... : BRP394 LED384/NW 320W 220-240V DM Lamp used .......................................................... : LED module as delivered Lamp control gear used ....................................... : Xi LP 150W 0.2-0.7A S1 230V S240 sXt Mounting position of luminaire.............................. : Normal mounting position Supply wattage (W) ............................................. : 327,8 Supply current (A) ............................................... : 1,38 Calculated power factor ....................................... : 0,989 Table: measured temperatures corrected for ta =35 C: - abnormal operating mode .................................. : The LED driver will shut down under output short-circuited - test 1: rated voltage ........................................... : -- test 2: 1,06 times rated voltage or 1,05 times 240 rated wattage ...................................................... : - test 3: Load on wiring to socket-outlet, 1,06 times 254,4 voltage or 1,05 times wattage .............................. : - test 4: 1,1 times rated voltage or 1,05 times rated -wattage ............................................................... : Through wiring or looping-in wiring loaded by a -current of A during the test .................................. : Temperature measurements, (C) Clause 12.4 – normal Part

Ambient

tc

test 1

--

64,8

       P      

Clause 12.5 – abnormal

test 2

test 3

--

--

limit 80

test 4

limit --

--

Supplementary information: 10 C has deducted from measured value

ANNEX 3

Screw terminals (part of the luminaire)

N/A

ANNEX 4

Screwless terminals (part of the luminaire)

(15.2)

Type of terminal......................................................:

Permanent connection



Rated current (A) ....................................................:

0,7 A



(15.3.1)

Material

>58 % copper

P

(15.3.2)

Clamping

P

(15.3.3)

Stop

P

(15.3.4)

Unprepared conductors

P

(15.3.5)

Pressure on insulating material

P

TRF No. IEC60598_2_3K

P

Page 44 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

(15.3.6)

Clear connection method

N/A

(15.3.7)

Clamping independently

N/A

(15.3.8)

Fixed in position

(15.3.10)

Result - Remark

Verdict

P 2

Conductor size

0,75 mm

Type of conductor

Flexible-stranded

P P

(15.5.1)

Terminals internal wiring

N/A

(15.5.1.1)

Pull test spring-type terminals (4 N, 4 samples).......:

N/A

(15.5.1.2)

Pull test pin or tab terminals (4 N, 4 samples) .........:

N/A

Insertion force not exceeding 50 N

N/A

(15.5.1.2)

Permanent connections: pull-off test (20 N)

P

(15.5.2)

Electrical tests

P

Voltage drop (mV) after 1 h (4 samples)..................:

#1:0,6 mA ;#2: 0,3 mA #3:0,3 mA; #4: 0,4mA

N/A

Voltage drop of two inseparable joints



Number of cycles: Voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................................:

th

10 cycles #1: 0,7 mA; #2: 0,4 mA #3: 0,3 mA; #4: 0,4 mA

(15.6)

(15.6.2.1)

P

N/A

Voltage drop (mV) after 50th alt. 100th cycle (4 samples) ............................................................: After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples) ............................................:

P

25th cycles #1: 1,3 mA; #2: 0,8 mA #3: 0,3 mA ; #4: 0,5 mA

P

After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples) ..........................................:

N/A

Terminals external wiring

N/A

Terminal size and rating

N/A

Pull test spring-type terminals or welded connections (4 samples); pull (N) ..............................................:

N/A

Pull test pin or tab terminals (4 samples); pull (N) ..................................................................:

N/A

TRF No. IEC60598_2_3K

Page 45 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

ATTACHMENT TO TEST REPORT IEC 60598-2-3 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Luminaires Part 2: Particular requirements Section 3 Luminaires for road and street lighting Differences according to ............... : EN 60598-2-3:2003 + A1:2011 used in conjunction with EN 60598-1:2015 Annex Form No. ............................ : EU_GD_IEC60598_2_1D Annex Form Originator ................. : OVE Master Annex Form....................... : 2015-04 Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

CENELEC COMMON MODIFICATIONS (EN)

P

1.5 (3)

MARKING

N/A

1.5 (3.3.101)

For luminaires not supplied with terminal block: Adequate warning on the package

N/A

1.6 (4)

CONSTRUCTION

N/A

1.6 (4.11.6)

Electro-mechanical contact systems

N/A

1.10 (5)

EXTERNAL AND INTERNAL WIRING

N/A

1.10 (5.2.1)

Connecting leads

N/A

- without a means for connection to the supply

N/A

- terminal block specified

N/A

- relevant information provided

N/A

- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1

N/A

Cables equal to EN 50525

N/A

Replace table 5.1 – Supply cord

N/A

ENDURANCE TESTS AND THERMAL TESTS

N/A

1.10 (5.2.2)

1.12 (12)

1.12 (12.4.2c) Thermal test (normal operation) see footnote c to table 12.2 relating to unsleeved fixed wiring

TRF No. IEC60598_2_3K

N/A

Page 46 of 70

Report No. 6005944.50

IEC 60598-2-3 Clause

Requirement + Test

Result - Remark

Verdict

ZB

ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN)

N/A

(3.3)

DK: power supply cords of class I luminaires with label

N/A

(4.5.1)

DK: socket-outlets

N/A

(5.2.1)

CY, DK, FI, GB: type of plug

N/A

ZC

ANNEX ZC, NATIONAL DEVIATIONS (EN)

N/A

(4 & 5)

FR: Shuttered socket-outlets 10/16A

N/A

FR: Safety requirements for high buildings (Arrêté du 30 décembre 2011 portant règlement de sécurité pour la construction des immeubles de grande hauteur et leur protection contre les risques d’incendie et de panique; Section VIII; Article GH 48, Eclairage)

N/A

Glow-wire test for outer parts of luminaires: - 850C for luminaires in stairways and horizontal travel paths

N/A

- 650C for indoor luminaires

N/A

GB: Requirements according to United Kingdom Building Regulation

N/A

TRF No. IEC60598_2_3K

Page 47 of 70

Report No. 6005944.50

Annex - IEC 62031 Clause 6

7 7.1

Requirement + Test CLASSIFICATION Built-in module .....................................................: Independent module..............................................: Integral module ....................................................: For Integral module; Note to 1.2.1 in IEC 60598-1 applies.

Result - Remark

Yes Yes Yes

No No No

Verdict P   

MARKING Mandatory markings: - mark of origin - model number, type reference ........................... : - rated supply voltage (V) ..................................... : - rated supply current (A) ..................................... : - rated input power (V) ......................................... : - nominal power - indication of connections, wiring diagram - value of tc - eye protection - marking of built-in modules only - location of marking

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

7.3

Marking durable and legible Rubbing 15 s water, marking legible

N/A N/A

8

SCREW TERMINALS

N/A

Compliance with section 14 of IEC 60598-1

N/A

7.2

P

SCREWLESS TERMINALS Compliance with section 15 of IEC 60598-1

9

See IEC 60598 part

P

CONNECTORS Compliance with IEC 60838-2-2

N/A N/A

PROVISION FOR PROTECTIVE EARTHING External metal parts connected to the earth terminal: - compliance with 7.2.1 in IEC 60598-1 Test with a current of 10 A between earthing terminal and each of the accessible metal parts; measured resistance (): < 0,5  .........................: Protective earth, symbol Terminal complying with clause 8 in Part 1 Locked against loosening and not possible to loosen by hand Not possible to loosen clamping means unintentionally on screwless terminals

N/A N/A N/A N/A

TRF No. IEC60598_2_3K

N/A N/A N/A N/A

Page 48 of 70

Report No. 6005944.50

Annex - IEC 62031 Clause

Requirement + Test

Result - Remark

Earthing via means of fixing Earthing terminal only used for the earthing of the control gear All parts of material minimizing the danger of electrolytic corrosion Made of brass or equivalent material Contact surface bare metal Conductors by tracks on printed circuit boards: - a.c. current of 25 A for 1 min between earthing terminal and accessible metal parts - compliance with clause 7.2.1 in IEC 60598-1

Verdict N/A N/A N/A N/A N/A N/A N/A N/A

8 (10)

PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS Protection against accidental contact with live parts in compliance with IEC 61347-1 (clause numbers between parentheses refer to IEC 61347-1) Refer to IEC 60598 part

P P

11

MOISTURE RESISTANCE AND INSULATION Protection against moisture and insulation in compliance with Clause 11, IEC 61347-1 After storage 48 h at 91-95% relative humidity and See IEC 60598 part 20-30 C measuring of insulation resistance with d.c. 500 V (M):  2 M .......................................: Adequate insulation between input and output terminals not bounded together in SELV-equivalent controlgear For double or reinforced insulation the resistance exceeds 4 M

P P P

12

13 13.1

ELECTRIC STRENGTH Electric strength in compliance with Clause 12 of IEC 61347-1 Immediately after clause 11 electric strength test for 1 min Working voltage  42 V, test voltage 500 V Working voltage > 42 V, test voltage (V): See IEC 60598 part 2U + 1000 V .........................................................: Reinforced insulation, test voltage (V): .................: No flashover or breakdown Windings in separating transformers in SELVequivalent control gear according to 14.3.2 of EN 60065 FAULT CONDITIONS In compliance with IEC 61347-1 (clause numbers between parentheses refer to IEC 61347-1) When operated under fault conditions the LED-module: - does not emit flames or molten material - does not produce flammable gases - protection against accidental contact not impaired Thermally protected controlgear does not exceed the marked temperature value Fault conditions: capacitors, resistors or inductors (see appended table)

TRF No. IEC60598_2_3K

N/A

N/A

P N/A N/A N/A P N/A N/A N/A

P P P P P P N/A N/A

Page 49 of 70

Report No. 6005944.50

Annex - IEC 62031 Clause

- (14.1)

- (14.2) - (14.3) - (14.4) - (14.5)

13.2

Requirement + Test without proof of compliance with relevant specifications have been short-circuited or disconnected Short-circuit of creepage distances and clearances if less than specified in clause 16 in Part 1 (except between live parts and accessible metal parts) Distances on printed boards provided with coating according to IEC 60664-3 Short-circuit or interruption of semiconductor devices Short-circuit across insulation consisting of lacquer, enamel or textile Short-circuit across electrolytic capacitors During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite After the tests the insulation resistance with d.c. 500 V (M) are  1 M ........................................: Temperature declared thermally protected LEDmodules fulfil the requirements in Annex C of IEC 61437-1 Module withstands overpower condition >15 min. Module with automatic protective device or power limiter, test performed 15 min. at limit. During the tests, tissue paper, spread below module, does not ignite

Result - Remark

(see appended table)

Verdict

N/A

N/A (see appended table)

P

(see appended table)

N/A

(see appended table)

N/A P

5000

P N/A

N/A N/A N/A

15

CONSTRUCTION Wood, cotton, silk, paper and similar fibrous material not used as insulation

P P

16

CREEPAGE DISTANCES AND CLEARANCES Creepage and distances and clearances in compliance with IEC 60598-1

P P

17 (17)

SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS Screws, current-carrying parts and connections in compliance with IEC 60598-1 (clause numbers between parentheses refer to IEC 60598-1)

P P

14 Part LED

TABLE: tests of fault conditions Simulated fault Short-circuited

TRF No. IEC60598_2_3K

P Hazard NO

Page 50 of 70

Report No. 6005944.50

Annex IEC 61347-2-11 for Surge protect device 2.0 output Clause 6 (6)

7 7.1 (7.1)

7.2 (7.1)

- (7.2)

8 (10) - (10.1) - (A2)

- (A2)

- (A3)

- (10.1)

- (10.2)

9 (8)

Requirement + Test

Result - Remark

CLASSIFICATION Independent controlgear ..................................... : Yes Built-in controlgear ............................................. : Yes Integral controlgear ............................................ : Yes

No No No

MARKING Mandatory markings (other than integral ballasts): - mark of origin - model number, type reference .......................... : - symbol for independent controlgear, if applicable - correlation between interchangeable parts and controlgear marked - legend on the controlgear - manufacturer’s catalogue - rated supply voltage (V) ................................... : - value of tc or ta - wiring diagram - earthing symbol - control terminals identified, if applicable - information to be provided, if applicable: - declaration on protection against accidental contact - cross-section of conductors (mm²) .................... : - number, type and wattage of lamp(s) Marking durable and legible Rubbing 15 s water, 15 s petroleum; marking legible

TRF No. IEC60598_2_3K

P    N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS Starting device protected against accidental contact with live parts The current flowing between the part concerned and earth is measured and does not exceed 0,7 mA (peak) or 2 mA d.c. ................................. : For frequencies above 1 kHz, the current does not exceed 0,7 mA (peak) multiplied by the value of the frequency in kilohertz or 70 mA (peak) ...... : The voltage between the part concerned and any accessible part is measured and does not exceed 34 V (peak) ......................................................... : Lacquer or enamel not used for protection or insulation Adequate mechanical strength on parts providing protection Capacitors > 0,5 F: voltage after 1 min (V): < 50 V ................................................................ : TERMINALS Separately approved, component list

Verdict

(see Annex 1)

P P N/A

N/A

N/A

P P N/A

P P

Page 51 of 70

Report No. 6005944.50

Annex IEC 61347-2-11 for Surge protect device 2.0 output Clause

Requirement + Test Screw terminals: compliance with Section 14 of IEC 60598-1 Screwless terminals: compliance with Section 15 of IEC 60598-1

10 (9)

14 (14)

- (14.1)

- (14.2) - (14.3) - (14.4) - (14.5)

Result - Remark

Verdict

(see Annex 2)

N/A

(see Annex 3)

N/A

PROVISION FOR EARTHING Terminal complying with clause 8 in Part 1 Locked against loosening and not possible to loosen by hand Not possible to loosen clamping means unintentionally on screwless terminals Earthing via means of fixing Earthing terminal only used for the earthing of the control gear All parts of material minimizing the danger of electrolytic corrosion Made of brass or equivalent material Contact surface bare metal Earth contact via the track on the printed board Test with a current of 25 A between earthing terminal and the accessible metal parts; measured resistance (): < 0,5  ....................... :

P P N/A

FAULT CONDITIONS When operated under fault conditions the controlgear: - does not emit flames or molten material - does not produce flammable gases - protection against accidental contact not impaired Thermally protected ballasts does not exceed the marked temperature value Fault conditions: capacitors, resistors or inductors (see appended table) without proof of compliance with relevant specifications have been short-circuited or disconnected Short-circuit of creepage distances and (see appended table) clearances if less than specified in clause 16 in Part 1 (except between live parts and accessible metal parts) Creepage distances on printed boards less than specified in clause 16 in Part 1 provided with coating according to IEC 60664-3 Short-circuit or interruption of semiconductor (see appended table) devices Short-circuit across insulation consisting of (see appended table) lacquer, enamel or textile Short-circuit across electrolytic capacitors (see appended table) After the tests has been carried out on three samples: The insulation resistance  1 M No flammable gases

N/A N/A N/A N/A N/A

TRF No. IEC60598_2_3K

N/A P N/A N/A N/A P N/A N/A

N/A N/A

N/A

N/A

N/A N/A N/A N/A N/A N/A

Page 52 of 70

Report No. 6005944.50

Annex IEC 61347-2-11 for Surge protect device 2.0 output Clause

- (14.6)

15 (15) 15.1 (15.1) 15.2 (15.2)

Requirement + Test

Result - Remark

No accessible parts have become live During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite Relevant fault condition tests with high-power supply CONSTRUCTION Wood, cotton, silk, paper and similar fibrous material not used as insulation Printed boards used as internal connections complies with clause 14 Insulating lining of metallic enclosures

Verdict N/A N/A 

P P P

N/A

17 (17)

SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS Screws, current-carrying parts and connections in compliance with IEC 60598-1 (clause numbers between parentheses refer to IEC 60598-1)

P P

18 (18) - (18.1)

RESISTANCE TO HEAT, FIRE AND TRACKING Parts of insulating material retaining live parts in position, ball-pressure test: - part; test temperature (C) ............................... : PCB; 125 - part; test temperature (C) ............................... : Enclosure; 75 Printed boards in accordance with 8.7 of IEC 61189-2 and relevant parts of IEC 61249-2 External parts of insulating material preventing Enclosure electric shock glow-wire test 650 C Parts of insulating material retaining live parts in position, needle-flame test 10 s: - flame extinguished within 30 s - no flaming drops igniting tissue paper Tracking test according section 13 of IEC 60598-1 if required

P P P P P

- (18.2) - (18.3) - (18.4)

- (18.5)

TRF No. IEC60598_2_3K

P N/A N/A N/A N/A

Page 53 of 70

Report No. 6005944.50

Annex model list Type Name

x

Housing

aaa

bb

ccc (W)

dddd

ee

fff

gg

tt

BRP39x LEDaaa/bb cccW 220-240V dddd ee fff gg tt hhh BRP39x LEDaaa/bb cccW 220-240V dddd ee fff gg tt hhh BRP39x LEDaaa/bb cccW 220-240V dddd ee fff gg tt hhh

1

Small

96 max

CW/NW/WW

80 max

PSU/ PSR/ PSD/ PSDD/ Nil

Nil

DM/DW1/ DW2/DWV/ DWP/ DWX/ DMV/DMP

Ni/P7/P1 CT or ANZ or Nil Nil

2

Middle

192 max

160 max

4

Large

384 max

320 max

Note: The explanation for model list BRP39x LEDaaa/bb cccW 220-240V ee fff dddd gg tt hhh or BRP39x cccW ff tt AMP-M) x=1 denotes small version housing, x=2 denotes middle version housing, x=4 denotes large version housing; LED denotes light source, could be blank aaa denotes rated lumen output, could be blank eg. aaa=150, the rated lumen output 15000lm bb denotes colour temperature, could be blank CW=Cool White NW=Neutral White WW=Warm White ccc denotes rated system power eg. ccc=150, the rated system power 150W dddd denotes : Driver Type, could be blank or PSU/PSR/PSD/PSA/PSDD/nil (The order of “dddd” and “ffff” can be exchanged) ee denotes type of insulation protection ; nil means class I, could be blank fff denotes Lens type: DM/DW1/DW2/ DWV/DWP/DWX/DMV/DMP gg denotes PE cell function: P1 and P7 means 7 pin NEMA socket application, tt denotes City Touch Application: CT = City Touch version/P 7 pin NEMA PE cell/nil hhh denotes country code: ANZ or nil nil means blank 220-240V means the voltage , could be blank AMP-M means client code, could be blank For example see next page.

TRF No. IEC60598_2_3K

hhh

AMPM

Client code

Page 54 of 70 Annex model list (partly) Model number BRP391 40W DM CT AMP-M BRP391 90W DM CT AMP-M BRP391 120W DM CT AMP-M BRP391 200W DM CT AMP-M

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 55 of 70 Annex circuit diagram and PCB layout

Surge protect device 2.0 output

Surge protect device 2.0 output

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 56 of 70 Annex instruction:

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 57 of 70 Annex instruction:

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 58 of 70 Annex instruction:

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 59 of 70 Annex instruction:

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 60 of 70 Annex instruction:

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 61 of 70 Annex pictures

Overview for all series

Overview for all series

TRF No. IEC60598_2_3K

Report No. 6005944.50

Page 62 of 70

Report No. 6005944.50

Annex pictures

Lock switch for BRP394 LED384/NW 320W 220-240V DM PSU

Spring locking for BRP394 LED384/NW 320W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 63 of 70

Report No. 6005944.50

Annex pictures

Internal view of supply compartment for BRP394 LED384/NW 320W 220-240V DM PSU

Terminal block for BRP394 LED384/NW 320W 220-240V DM PSU (insulation sheet is under the terminal block)

TRF No. IEC60598_2_3K

Page 64 of 70

Report No. 6005944.50

Annex pictures

Gland for BRP394 LED384/NW 320W 220-240V DM PSU

LED driver in position for BRP394 LED384/NW 320W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 65 of 70

Report No. 6005944.50

Annex pictures

Earthing terminal on the top cover for BRP394 LED384/NW 320W 220-240V DM PSU

Another earthing terminal on the cover for BRP394 LED384/NW 320W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 66 of 70

Report No. 6005944.50

Annex pictures

Earthing terminal on the metal enclosure for BRP394 LED384/NW 320W 220-240V DM PSU

Device fixing lens (used only once) for BRP394 LED384/NW 320W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 67 of 70

Report No. 6005944.50

Annex pictures

LED module for BRP394 LED384/NW 320W 220-240V DM PSU

Internal wire to connector (wrapped by sleeve) for BRP394 LED384/NW 320W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 68 of 70

Report No. 6005944.50

Annex pictures

Internal view for BRP392 LED192/NW 160W 220-240V DM PSR

Internal view for BRP391 LED60/NW 50W 220-240V DM PSU

TRF No. IEC60598_2_3K

Page 69 of 70

Report No. 6005944.50

Annex pictures

BRP394 LED384/NW 320W 220-240V DM PSR P1 with NEMA socket

Internal view for BRP394 LED384/NW 320W 220-240V DM PSR P1

TRF No. IEC60598_2_3K

Page 70 of 70

Report No. 6005944.50

Annex pictures

NEMA socket with CT controller for BRP394 LED384/NW 320W 220-240V DM PSR P7 CT

PCB for CT controller -------------------------------------------------------------------END--------------------------------------------------------------------

TRF No. IEC60598_2_3K