Increase productivity by reducing loading/unloading time



More cost effective with configurable sample holding system

      

Closed loop laser Touch screen interface Configurable sample holding system Drop load samples Auto calibration Programmable spot size And more...

The new configurable drop loading catheter holding system allows fast loading/unloading. Right chuck can be a segmented chuck with 0-1/4” opening, touhy borst or three jaw micro chuck. Air driven adjustable opening catheter clamp on the left. See other configurations on separate page. Adjustable position catheter support trough is standard.

Pioneers in catheter laser bonder development since 2002 with 30+ loyal customers around the world

Direct drive spindle accepts various types of holding chucks, allow speed change from 0 to 1500 RPM, variable speed jogging with joystick

Motorized beam delivery system allowing spot size to be programmed in every step of a bonding recipe

Choice of Chucks

Three jaw stainless steel gapless chuck,

Touhy borst chuck, 3 sizes: 1-5 Fr, 5-7

opening 0-1mm, high precision. Best used

Fr, 7-9 Fr., Directly hold tubing with

to hold mandrel directly

rubber ring

6 segmented chuck, 0-1/4” opening, plastic segments, directly hold tubing and/or mandrel, easy loading/unloading

Touch Screen Shots

Equipped with a 7”, high resolution touch-screen controller, programming the LBS 5000 is easier than ever.* The touch screen HMI also supports multiple language * These screens are highly dynamic. They work similar to a Microsoft Window program

INNOVA DESIGN, INC. 9883 Pacific Heights Blvd., Suite A San Diego, CA 92121 USA

Phone: (858)535-9389 Fax: (888)308-7330 E-mail: [email protected] Website: www.laser-bonder.com

LBS5000 Sample Holding System Configurations

CONFIG #1: Spindle on the right side, clamp on the left side. Recommended to use with catheters with short to medium length balloons. Any types of chuck can be installed on the spindle. The chuck will hold the distal end of the support mandrel and rotate. Clamp will hold the proximal side of the balloon as a guide. Allow quick drop loading.

CONFIG #2: Spindle on the left side, clamp on the right side. Recommended to use with catheters with short to medium length balloons and non-circular shaft tubing. Recommend to use segmented or touhy borst chucks on the spindle. The chuck will hold the proximal side of the balloon and rotate. Clamp will hold the distal end of the support mandrel.

CONFIG #3: Spindle on the left side, dual clamps on each side of the balloon. Recommended to use with catheters with short to long length balloons and long shaft. Recommend to use the segmented or touhy borst chucks on the spindle. The chuck will hold the proximal end of the catheter. Clamps will hold both proximal and distal end of the balloon. Allow drop-in loading, efficient and precise

CONFIG #4: Dual spindle for holding catheters with built in guide wire or without through inner lumen, or for long and large size catheters OTHER CONFIGURATIONS: More configurations are possible, for example, by using more than two clamp for long and thicker catheters to prevent excessive wobbling,

INNOVA DESIGN, INC. 9883 Pacific Heights Blvd., Suite A San Diego, CA 92121 USA

Phone: (858)535-9389 Fax: (888)308-7330 E-mail: [email protected] Website: www.laser-bonder.com

LBS5000 Laser Bonder Feature Comparisons FEATURES \\ MODELS

LBS5100

LBS5200

LBS5300

10W CO2 Laser







Closed Loop Laser with 2% Stability







Real Time power Display







Electronic Shutter to eliminate power surge







Auto Power Calibration Software Module







Configurable sample holding system







Support catheter drop loading/unloading













Dual direct drive spindles

Optional

Optional

Optional

Multiple catheter clamps

Optional

Optional

Optional

Standard configuration: Catheter clamp + direct drive spindle







Stackable Lens System







Programmable Spot Size in Each Step with Motorized Lens

N/A

N/A



7” High Resolution Touch Screen Controller







Multi Language Support







Built-in Cross Hair Generator







Machine Vision System with built-in 15” LCD Monitor







Optional

Optional

Optional

Process and Calibration Data Reporting to PC







Powered Safety Door Open/Close







Serial Multi-Step Bonding Recipe Interface







Free Tech Support







Life Time Software Update







Parallel beam with slot aperture

Automatic Recipe Selection with Barcode Scanner

Heat Shrink Tubing Polyolefin Shrink Tubing P/N

Min. Expanded ID (in)

Max. Recovered ID (in)

ST-MD-201

0.043

0.012

ST-MD-202

0.060

0.016

ST-MD-203

0.082

0.029

ST-MD-204

0.093

0.034

ST-MD-205

0.120

0.037

Want more? We provide specialized shrink tubing for laser bonding Check our customization programs

New to laser bonding? No problem. We provide training and process development We also offer bonding services for small quantities

Some Samples†:

n

er Tap

tac p At

Ti Soft

t

n hme

PU

Bal

loo

ti o ma r o F

nB ond

† These represent only part of the capabilities of our laser bonder

INNOVA DESIGN, INC. 9883 Pacific Heights Blvd., Suite A San Diego, CA 92121 USA

Phone: (858)535-9389 Fax: (888)308-7330 E-mail: [email protected] Website: www.laser-bonder.com

d g an ppin a r tW ng Sten ip Bondi T