Variable Refrigerant Flow System Multi Air Conditioning System for Buildings

The Intelligent Choice in Comfort SERIES

N807

All products specified in this brochure comply with the Australian Communications Authority's (ACA) requirements for Electromagnetic Compatibility (EMC).

“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED. *Microsoft ® and Windows ® are registered trademarks of Microsoft Corporation in the United States. *Adobe® and Acrobat Reader ® are registered trademarks of Adobe Systems Incorporated in the United States. *Intel ®, Pentium ® and Celeron® are registered trademark of Intel Corporation or its subsidiaries in the United States. *AMD AthlonTM and AMD DuronTM are registered trademark of Advanced Micro Devices, Inc. *Echelon ®, LON ®, LONWORKS ®, LonTalk ®, Neuron ®, 3120 ®, 3150 ®, LNS ®, i.LON ®, LonMaker ®, and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *BACnet ® is a registered trademark of the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE).

*An XLON ® USB adaptor is provided. (XLON ® is a registered trademark of DH electronics company Gmbh.) All specifications subject to change without prior notice.

Copyright

2002-2005 Fujitsu General Limited. All rights reserved.

Distributed by :

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan URL : http://www.fujitsu-general.com VB008E/05 Printed in Japan

Variable Refrigerant Flow System

Building air conditioning de Providing highly efficient, energy-saving operation.

RB (Refrigerant Branch) Unit

HEAT PUMP & COOLING ONLY SERIES

Flange [Square] Model : UTD-SF045T For low pressure duct type 205 x 1,063, L=40 (mm)

Multi Type Model : UTF-Y90A4A

[Round] Model : UTD-RF204 For low pressure duct type 195 ( 205), L=85 (mm) Single Type Model : UTF-Y54A1A

A high-performance operating system utilising innovative triple high-efficiency compressors and advanced refrigerant flow control technology (Power Balance Technology). The result is superior energy savings and impressively low operating noise. Capable of connecting up to 13 (22.4kW) or 16 (28kW) indoor units to one outdoor unit.

Outlet chamber Separation tube

For Heat recovery Model : UTR-BP90MA UTR-BP54MA Separation tubes are available for installation as necessary.

Flexible duct Model : UTD-RD202 For high static pressure duct type 200, L=2m

For Heat pump / Cooling only Model : UTR-BP90TA UTR-BP54TA Separation tubes are available for installation as necessary.

OUTDOOR UNITS LINE UP

R407C

Model : UTD-BC200 195 ( 200), L=85, Base size: H x W x D (mm) 297 x 1,066 x 400

R22

Drain water riser kit Header

Heat Pump Type

Cooling Only Type

Heat Pump Type

Cooling Only Type

AO90TPCMF(28kW) AO72TPCMF(22.4kW)

AO90EPCMF(28kW) AO72EPCMF(22.4kW)

AO90RPCMF(28kW) AO72RPCMF(22.4kW)

AO90APCMF(28kW) AO72APCMF(22.4kW)

For Heat pump / Cooling only Model : UTR-HD908A For Heat recovery Model : UTR-HD908R Headers are available for installation as necessary. *Reducer is attached to each header kit.

INDOOR UNIT

INDOOR UNITS LINE UP

Heat pump / Cooling only Model : UTR-HD906A For Heat recovery Model : UTR-HD906R Headers are available for installation as necessary.

Choose the right indoor unit to match the building requirements. Various combinations of indoor unit type and capacity 12 types 45 models, ranging from 2.15kW to 17.0kW.

Cassette Type (Compact) Cassette Type

Duct Type (Compact)

Duct Type

Model : UTR-DPB241 For ceiling type

Long-life filter Model : UTD-LF270 For low static pressure duct type Model : UTD-LF400 For high static pressure duct type

*Reducer is attached to each header kit.

High Static Pressure Duct Type

Remote sensor unit Grille kit

Slim cassette designed for restricted ceiling voids.

Slim Type

Compact design for easy installation and maintenance Compact but powerful for all user applications. see page 26

2

see page 27

Equally suitable for ceiling installation or at floor level.

Ultra-slim duct air conditioner for those tight ceiling spaces.

High static pressure duct type with no installation restrictions.

see page 28

see page 28

see page 29

Model: UTG-UDYD-W UTG-UDGD-W Grille for compact cassette type indoor unit.

Model : UTD-RS100 Thermo-sensor for sensing the temperature of arbitrary place in the room

39

TM

Optional Parts Network Convertor

Model : UTR-YRDA

veloped to care for people As for the other optional parts, refer to the other page of this catalog.

Network Convertor

This network convertor is to be used for connecting single split system or group remote controller with the VRF system. Please select the function by switching the dip switch during the installation work.

Dimensions (mm) (H x W x D) : 67 x 288 x 211 Weight (g) : 1,500 .Split type systems can be controlled from a central remote controller or PC controller by connecting it to the VRF’s network convertor. .Standard remote controller and central remote controller provide On/Off control, master control, temperature and fan control, etc. .Up to 16 single units can be contnected to and controlled with Network convertor. .Up to 100 units of Network convertor can be connected in a single VRF transmission system. Network convertor (UTR-YRDA)

SET TIME

FAN CONTROL

TEMP./DAY

MASTER CONTROL

TIMER MODE

SET TIME

TEMP./DAY

FAN CONTROL

MASTER CONTROL

CLOCK ADJUST

ZONE SET

ENERGY SAVE START/STOP DAY OFF

ZONE SET

ENERGY SAVE START/STOP DAY OFF

Group of Single Split

HEAT RECOVERY SERIES

.For connection between VRF system and a LONWORKS open network for the management of a small to medium-sized BMS and VRF system. .By using the UTR-YLLA, the VRF system can be centrally controlled or monitored from a BMS with a LONWORKS interface. .Up to 128 Indoor units can be connected to 1 unit of Network Convertor.

A high-performance operating system utilising innovative triple high-efficiency compressors and advanced refrigerant flow control technology (Power Accumulation Technology). With heat recovery operation, cooling and heating can be performed simultaneously and automatically within the same refrigerant system. This approach provides maximum energy efficiencies. Capable of connecting up to 16 (28kW) indoor units to one outdoor unit.

Maximum 128 units

General-purpose building control computer (LONWORKS device)

Lighting facilities TIMER MODE

Model : UTR-YLLA Dimensions (mm) (H x W x D) : 67 x 288 x 211 Weight (g) : 1,500

LONWORKS Network

CLOCK ADJUST

Non-inverter system free of electrical noise emissions.

Network convertor (UTR-YLLA)

VRF System Network

VRF system Maximum 128 units

Security system Automatic fire alarm interface

TIMER MODE

SET TIME

TEMP./DAY

FAN CONTROL

MASTER CONTROL

CLOCK ADJUST

ZONE SET

ENERGY SAVE START/STOP DAY OFF

Ventilation system

VRF system

Single Split

TIMER MODE

SET TIME

TEMP./DAY

FAN CONTROL

VRF system

Big Multi

MASTER CONTROL

CLOCK ADJUST

ZONE SET

VRF System Network

ENERGY SAVE START/STOP DAY OFF

OUTDOOR UNIT .For connection between Group remote controller and VRF system.

Transmission Adaptor

Dimensions (mm) (H x W x D) : 100 x 288 x 110 Weight (g) : 1,300

Group remote controller UTB-YDA / UTB-GDA

Network convertor (UTR-YRDA)

BACnet Gateway [Software]

Model : UTR-YTMA

R407C

Model : UTR-YLBA

.The central control of maximum 1600 indoor units can be realized by connecting the VRF system to the BACnet, a global standard of the open network .ANSI / ASHRAE Standards 135-2001BACnet Application Specific Controller (B-ASC) BACnet / IP over Ethernet .It can be connected up to 4 systems (1600 indoor units / 400 outdoor units) for 1 gateway. .It can be corresponded to the large-scale buildings and hotels etc. BACnet ® Operator Workstation (B-OWS) VRF system 1

.For the air condition of the medium and large size building, the control software can control and monitor the air conditioners together with the ones in the other buildings. .This device enables control by other equipment via an Inter Link cable.

Signal Amplifier

Heat Recovery Type AO90MPBMF(28kW)

Model : UTR-YRPC Dimensions (mm) (H x W x D) : 67 x 288 x 211 Weight (g) : 1,500

USB Adaptor Indoor unit

Outdoor unit

BACnet Gateway (UTR-YLBA)

VRF system 2

BACnet

USB Adaptor Indoor unit

Outdoor unit

CD-ROM (Software)

Software Protection Key

USB Adaptor

Lighting facilities Security system Automatic fire alarm interface Ventilation system

(Max. 4 systems) USB Adaptor

= BACnet corresponding interface of each company

*USB Adaptor is XLON USB Adaptor of DH electronics company. **Twisted pair cable [22AWG(0.65mm) Level 4 shielded cable recommendation]

38

.This unit allows the connection of the following number of units: (1) Transmission Line : Max. 2000m (2) Connectable Units : Max. Indoor Unit : 400 units Max. Outdoor Unit : 100 units Max. Central Remote Controller : 16 unit .Up to 8 signal amplifiers can be installed in a single VRF system. .A signal amplifier is required, (1) When the total wiring length of the transmission line exceeds 500m. (2) When the total number of devices on the transmission line exceeds 62.

Floor & Ceiling Universal Type

Ceiling Type

This slim unit can be ceiling mounted or installed floor standing. Features double auto swing louvers.

Attractive design and ultra-slim build still permits extra wide air flow. Features double auto swing louvers and extremely quite.

see page 29

see page 30

Wall Mounted Type (Compact)

Vertical and horizontal symmetrical design matched to the interior decor. Wall Mounted Type (Compact) indoor unit can't be operated in the Heat Recovery Type System. see page 30

Wall Mounted Type

Ceiling Wall Type

"Double Auto Swing" feature provides Omni-Directional Air Flow control

Discreet air intake is part of its attractive design. Double auto swing louvers.

see page 31

see page 31

3

Variable Refrigerant Flow System

TM

New operating system achieves high stan R407C

Heat Pump Type

Cooling Only Type

AO90TPCMF(28kW) AO72TPCMF(22.4kW)

AO90EPCMF(28kW) AO72EPCMF(22.4kW)

R22

Heat Pump Type

Cooling Only Type

AO90RPCMF(28kW) AO72RPCMF(22.4kW)

AO90APCMF(28kW) AO72APCMF(22.4kW)

Web Monitoring Tool Model : UTR-YMSA [Option]

Product features Dual casing bell mouth

[Software]

Features

Trouble-shooting is performed by monitoring each air conditioning unit remotely during periodical system checks. System Status & Error Information

Web Monitoring System Large propeller fan

Remote Side

VRF System Side Outdoor unit

Monitoring center

V shaped heat exchanger unit

VRF system

Remote side

Internet explorer 6.0 or later Internet (Provider)

UTR-YMSA

or

Public Telephone Line Indoor unit

Intelligent control circuit

VRF System side

Error notification can be automatically transmitted to several locations using the internet*. Requires either a dedicated internet connection* or public telephone line. Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location. The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in off-line mode of the service tool. * Unchanging global IP address is required.

3 compressor system Sales Company

Installer

Supprot 4 VRF system PC Transmission adaptors (max. four adaptors per PC) permit control and monitoring of up to 1,600 units. Suitable for large-scale buildings or hotels.

System components

High Efficiency System New operating system

3.10 3.71

Cooling COP Heating COP

Outdoor Unit

Oil Separator

Required capacity

Compressor capacity control is achieved through the optimum balance of three individually rated compressors. This approach is extremely efficient as it provides a wide range of refrigerant flow High rate options. Furthermore, 1 by controlling the amount of gas pumped by each 1 2 2 compressor, the system can accurately adjust refrigerant flow rates.

4

2

3

3

3

Internet or Public Telephone Line

Software Protection Key Transmission

Adaptor (UTR-YTMA) or USB adaptor (Field Supplied)

Internet explorer 6.0 or later

Personal Computer (Field Supplied)

Interlink Cable (Field Supplied)

Valve

Comp 2

Power loss

Capacity or Power input

Gas

Operating System Valve

Personal Computer

Liquid

Receiver Tank

Low pressure control for cooling

High pressure control for heating Insufficient capacity

Insufficient capacity

Capacity or Power input

Power loss

New control range

New control range

Conventional control range

Conventional control range

(-)

(+)

Target value

Low pressure

Max.400

Max.400

Max.400

Max.400

H.E. E.V.

Accumulator Tank

Heat Exchanger

VRF System1 VRF System2 VRF System3 VRF System4 Indoor unit Indoor unit Indoor unit Indoor unit

Requirements of PC for this software

LP

Expansion Valve

3

High Operating capacity

Indoor Unit

Comp 1

HP

Comp 3

1

Software

(UTR-YMSA)

VRF System

Compressor Capacity Control

low

(User Side)

(Field Supplied)

Power balance control technology achieves high operational efficiencies by detecting low pressure (evaporating temperature) during cooling and high pressure (condensing temperature) during heating and precisely controls the optimum refrigerant condition via refrigerant flow rate (capacity). Waste through excessive refrigerant flow is eliminated as is insufficient capacity due to insufficient refrigerant flow rate.

(AO90TPCMF)

COP values are base on our own testing method.

VRF System Side

Personal Computer

Power Balance Control

The newly developed operating system controls the refrigerant flow rate inside the refrigerant circuit through the use of dual control technology, i.e. compressor capacity control technology and power balance control technology. This approach delivers high operating efficiencies through optimum refrigerant flow.

Remote Side (Monitoring Center)

(-)

Hardware

Packing List (+)

Target value

Software

High pressure

AT compatible machine that runs Microsoft Windows . Microsoft Windows 2000 Professional (English version / Service pack3 or later) . Microsoft Windows XP Professional (English version / Service pack1 or later) TM

TM

CPU HDD Memory

Intel Pentium / Celeron , AMD Athlon / Duron 1GHz or higher 2.1 GB or more 512 MB or more

Interface

Serial port (Max. 4)*1 and USB port Internet Explorer 6.0 or later / Adobe

Acrobat . Interlink cable D-sub 9pin [Field supplied] . Transmission Adaptor (UTR-YTMA)

Reader 4.0 or later *2

CD-ROM / Software Protection Key

*1 1 port required for each VRF system connected. *2 If Internet Explorer is installed on the remote side PC, remote supervision of VRF system status is available.

37

Variable Refrigerant Flow System

TM

dards in comfort and performance

[Software]

Model : UTR-YSTC [Option]

Selectable Operation Mode

Extensive monitoring and analysis functions for installation and maintenance Outdoor unit

Transmission adaptor

Service Tool

15%

Energy saving

Comp.1 High-power mode Energy saving mode

High-power mode Energy saving mode

Comp.2 15% energy saving

15% quicker Power Consumption

High power mode enables set point to be achieved much quicker (approx 15% faster).

Functions

Time

Energy saving mode discreetly adjusts room temperature to achieve a valuable 15% energy saving.

Commissioning tool

Displays the schematic, sensor values, and electrical components operating status of the selected unit. Normal operation checks and cause specification when an error occurs are performed.

Wide Operating Range Cooling + heating operation at low outdoor temperature of down to -15 C Outdoor unit operates over an outdoor temperature range of -15 C to 52 C for cooling and -15 C to 21 C for heating.

Error history

Test run commands can be executed with this tool. During test running, the outdoor unit/indoor unit sensor data can be saved (commissioning log data). After the end of test running, this data can be exported in CSV file format.

Displays the error information for each unit. The error information cansequentially display up to 50 items beginning from the newest error for each unit.

Requirements of PC for this software AT compatible machine that runs Microsoft Operating System CPU HDD Memory Interface

Oil Recovery operation After a fixed period of time the oil recovery operation automatically returns accumulated oil found in the refrigerant circuit and indoor units.

52 C 50 40

Heating

30

21 C

Surroundings Conscious

20

No Harmonic Disturbances

10 0

As our VRF system is not based on inverter technology to control refrigerant flow rate harmonic emissions are almost zero. As a result, it will not interfere with electronic equipment found in the office, factory or power distribution facilities, making it the ideal air conditioning solution for hospitals where harmonic emissions are strictly controlled.

-10 -15 C

Super Quiet

36

Indoor Unit Each indoor unit operates independently from the others and is, therefore, not affected by a failure within any part of the network.

Cooling

-15 C

Packing List

Comp.3

Equipment detail Displays the overall operating status from a list of the status of each unit.

Software Hardware

Outdoor Unit In the event of compressor failure an alarm is automatically triggered and the remaining compressor(s) will continue to operate, thereby ensuring continuous operation when possible.

Indoor unit

Temperature

Refrigerant piping

(Field supplied)

High power and energy saving modes are freely selectable and have the effect of varying the outlet air flow temperature by 2 degrees. The energy saving mode delivers 15% energy savings, whereas the high power mode increases capacity by an equal amount.

Time

Personal Computer

High Reliability Recovery operation

High power and energy saving

or USB adaptor

Indoor unit

System list

HEAT PUMP & COOLING ONLY SERIES

(UTR-YTMA)

Transmission line

. Operational status can be checked and analyzed to detect even the smallest abnormalities. . Storage of data on system operating status on a PC allows access even from off site. . Up to 400 units (a single VRF system) can be controlled and monitored for large scale buildings or hotels.

Temperature

Service Tool

Low sound pressure level

Harmful effects

Windows

Microsoft Windows 2000 Professional (English version / Service pack3 or later) Microsoft Windows XP Professional (English version / Service pack1 or later) TM TM Intel Pentium / Celeron , AMD Athlon / Duron 1GHz or higher 2.1 GB or more

256 MB or more Serial port and USB port Internet Explorer 6.0 or later / Adobe Acrobat Reader 4.0 or later Interlink cable D-sub 9pin [Field supplied] / Transmission Adaptor (UTR-YTMA)

Operational noise has been reduced yet further through the application of a new dual casing bell-mouth and large fan. When set to silent operation, noise levels can be reduced by 56dB(A) compared to normal operation.

Normal operation mode Silent operation mode

28kW

22.4kW

55 dB(A) 50 dB(A)

54 dB(A) 48 dB(A)

Office automation Power distribution facilities. Factory automation

(380V) CD-ROM / Software Protection Key

5

Variable Refrigerant Flow System

TM

Maximum comfort from inbuilt flex

Wall Mounted Type (Compact) / Wall Mounted Type Model

R407C

Heat Recovery Type

AS7

Wall Mounted Type (Compact) AS9 AS12

AS14

AO90MPBMF(28kW) Cooling Capacity Heating Capacity

kW

2.15

2.80

3.50

3.80

5.40

6.90

8.00

BTU / h

7,400

9,600

11,900

13,000

18,400

23,600

27,300

kW

2.45

3.10

4.10

4.50

5.60

7.80

8.80

BTU / h

8,400

10,600

14,000

15,400

19,100

26,600

30,000

W

26

30

35

39

38

50

60

Current

A

0.15

0.16

0.18

0.20

0.18

0.24

0.28

A

0.18

0.19

0.22

0.24

0.22

0.29

0.34

410

450

520

540

840

950

1,050 940

High Air Circulation

Fan Speed

m3/h

380

410

500

510

700

800

Low

350

370

470

490

600

670

780

High

1,000

1,090

1,250

1,300

1,080

1,190

1,320

930

1,000

1,200

1,240

940

1,030

1,210

860

900

1,150

1,180

810

900

1,030

Med

Med

r.p.m.

Low High Noise Level (Sound Pressure)

16.5

W

Fan Motor Output

Med

dB (A)

Low

30

33

37

38

42

45

48

28

30

36

37

39

42

45

26

27

34

35

35

38

42

Cross Flow x 1 Plate Fin Coil

Heat Exchanger Dimensions (H x W x D)

Net

mm

Gross Weights

Net

257 x 808 x 187

320 x 1,120 x 220

270 x 850 x 310

348 x 1,240 x 427

8

16

kg

Gross Pipe Size

Liquid

10

22 6.35

mm

Gas

9.52

9.52

12.70

Cooling

C

16 to 30

Ceiling Wall Type Model

Heating COP

(AO90MPBMF)

COP values are base on our own testing method.

AW7

Power Accumulation Technology Flow rate to the indoor unit(s) is controlled through the use of 3 differently rated compressors operating in a sequential step arrangement.While power accumulation technology controls the circulating load of the refrigerant flow between those steps.

Heating Capacity

2.15

2.80

3.60

4.30

5.40

6.90

8.00

9,600

12,300

14,700

18,400

23,600

27,300

kW

2.45

3.10

4.10

4.90

5.60

7.80

8.80

BTU / h

8,400

10,600

14,000

16,700

19,100

26,600

30,000

20

W

16

19

A

0.08

0.09

A

0.10

0.11

380

480

600

650

330

420

520

Low

290

390

High

1,090

Max. Current High Med

Med

m3/h

r.p.m.

High Med

30

40

50

0.14

0.19

0.24

0.17

0.23

0.29

760

900

950

570

660

780

870

470

490

560

650

780

1,310

950

1,000

1,150

1,300

1,380

980

1,180

860

910

1,030

1,160

1,280

900

1,100

800

820

930

1,020

1,180

37

40

44

47

35

37

41

45

32

34

37

42

35

34

30

31

Required capacity

Cross Flow x 1

Heat Exchanger 1

Dimensions (H x W x D)

1

2

2

Plate Fin Coil Net

270 x 1,150 x 285

mm

Gross

Flow of refrigerant Comp.2

Power accumulation technology

Weights

Net

400 x 1,260 x 380 16

kg

Gross Pipe Size

Comp.2

Liquid

20 6.35

mm

Gas

9.52

Pipe Connection Method 1 low Comp.3

2

3

3

3

3

High Operating capacity

Flow rate between each step is controlled by power accumulation technology

6

Operation Range

9.52

12.70

15.88 Flare

Cooling

C

Heating Comp.3

33

32

Fan Type x Q'ty

Comp.1

0.12

32

dB (A)

Low

High

21 0.10

W

Fan Motor Output

Comp.1

AW30

7,400

Current

Noise Level (Sound Pressure)

AW24

kW

Input

Air Circulation

AW18

BTU / h

Low

The configuration of 3 constant speed compressors with differing capacities and power accumulation technology ensure smooth step changes and highly efficient operation.

Ceiling Wall Type AW14 220-240V~50Hz

Cooling Capacity

Fan Speed

Power accumulation technology

AW12

AW9

Power Source

Diagram

Smooth operation delivering high efficiencies

18 to 30

Heating

Operating system

2.98 3.15

15.88 Flare

Pipe Connection Method Operation Range

Wall Mounted Type (Compact) indoor unit can't be operated in the Heat Recovery Type System.

38

Fan Type x Q'ty

Cooling COP

AS30

Input

Max. Current

Cooling and heating can be performed simultaneously within the same refrigerant circuit. Energy savings are made by transferring heat between the indoor units when in heat recovery operation.

Wall Mounted Type AS24

220-240V~50Hz

Power Source

High Efficiency System

AS18

18 to 30 16 to 30

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating : Indoor temperature of 20 CDB/(15) CWB, and outdoor temperature of 7 CDB/6 CWB.

35

Variable Refrigerant Flow System

TM

Specifications

ibility

High Static Pressure Duct Type Model

High Static Pressure Duct Type AR45H

AR36H

AR60H

220-240V~50Hz

Power Source Cooling Capacity

kW

10.5

12.7

17.0

BTU / h

36,000

43,500

58,000

kW

10.7

13.7

17.6

BTU / h

36,500

47,000

60,100

Input

W

445

Current

A

Heating Capacity

Fan Speed

m3/h

2,200

3,000

1,700

1,900

2,750

Low

1,400

1,600

2,500

High

760

890

1,150

690

820

1,075

630

760

1,000

Med

Med

r.p.m.

Low Fan Motor Output

350

W

Med

45

dB (A)

Dimensions (H x W x D)

mm

Weights

Net

Liquid

-10

19.05

Super Quiet

18 to 30

C

Heating

16 to 30

Low sound pressure level

Floor & Ceiling Universal Type / Ceiling Type Floor & Ceiling Universal Type

Model

AB12

AB14

AB18

Ceiling Type AB24

AB30

AB36

AB45

AB54

220-240V~50Hz

Power Source

Heating Capacity

kW

3.5

4.05

5.3

6.6

8.8

10.5

12.7

14.1

BTU / h

11,900

13,800

18,100

22,500

30,000

36,000

43,500

48,200

kW

4.1

5.0

5.6

7.7

9.1

10.7

13.7

15.8

BTU / h

14,000

17,100

19,100

26,300

31,000

36,500

47,000

54,000

Input

W

57

88

124

144

160

180

Current

A

0.25

0.38

1.14

1.16

1.17

Max. Current

A

0.30

0.45

1.36

1.39

1.40

High Air Circulation

Fan Speed

Med

m3/h

770

900

1,620

1,890

2,110

2,350

680

780

1,540

1,710

1,890

2,810

480

560

660

1,360

1,450

1,630

1,900

High

850

1,030

1,180

850

1,000

1,100

1,250

760

890

1,040

800

900

1,000

1,150

670

770

900

700

750

850

1,000

16

30

40

40

46

49

41.5

47

50

52

37

41.5

45

38

44

48

50

34

37

41

34.5

39

44

46

r.p.m.

W

Fan Motor Output High Noise Level (Sound Pressure)

640 560

Low

Med

dB (A)

Low Fan Type x Q'ty Heat Exchanger Dimensions (H x W x D)

mm

Net

Liquid

318 x 1,800 x 790

320 x 1,150 x 790 28

kg

37

30

48

39

61

6.35

mm

Gas

12.70

9.52 15.88

19.05

Normal operation mode

55 dB(A)

Silent operation mode

50 dB(A)

Comfortable Operation Heat Recovery operation Heat Recovery operation is a cooling/heating free operation system, cooling and heating can be performed simultaneously in the same refrigerant system according to user needs. At the moment, The Heat Recovery operation is an extremely superior type that provides a still greater energy saving effect by moving heat between indoor units that are performing the cooling and heating operations. This is by having the compressors act like a pump.

Oil Recovery operation After a fixed period of time the oil recovery operation automatically returns accumulated oil found in the refrigerant circuit and indoor units.

Surroundings Conscious No Harmonic Disturbances As our VRF system is not based on inverter technology to control refrigerant flow rate harmonic emissions are almost zero. As a result, it will not interfere with electronic equipment found in the office, factory or power distribution facilities, making it the ideal air conditioning solution for hospitals where harmonic emissions are strictly controlled.

Harmful effects

Office automation Power distribution facilities.

Flare

Pipe Connection Method Operation Range

240 x 1,660 x 700

199 x 990 x 655

Gross Pipe Size

Sirocco x 4 Plate Fin Coil

Net Gross

Weights

160

Sirocco x 2

Operational noise has been reduced yet further through the application of a new dual casing bell-mouth and large fan. When set to silent operation, noise levels can be reduced by 5dB(A) compared to normal operation.

(380V)

Low

Med

Indoor Unit Each indoor unit operates independently from the others and is, therefore, not affected by a failure within any part of the network.

9.52

mm

Flare

Cooling Capacity

Comp.3

90

Gas

Cooling

Comp.2 -5 C -15 C

75

kg

Pipe Connection Method Operation Range

Comp.1

500 x 1,430 x 930

Gross Pipe Size

21 C

0

400 x 1,250 x 800

Gross

Heating

10

332

Plate Fin Coil Net

40

20

51

Sirocco x 2

Heat Exchanger

52 C 50

30

52

44

Fan Type x Q'ty

Outdoor Unit In the event of compressor failure an alarm is automatically triggered and the remaining compressor(s) will continue to operate, thereby ensuring continuous operation when possible.

Cooling

53

46

43

Low

Outdoor unit operates over an outdoor temperature range of -5 C to 52 C for cooling and -15 C to 21 C for heating.

500 48

47

High Noise Level (Sound Pressure)

4.81

2,000

High Reliability Recovery operation

Cooling operation at outdoor temperatures down to -5°C

3.58

3.02

High

Wide Operating Range

733

463 2.35

A

Max. Current

Air Circulation

HEAT RECOVERY SERIES

Cooling Heating

C

18 to 30 16 to 30

Factory automation

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating : Indoor temperature of 20 CDB/(15) CWB, and outdoor temperature of 7 CDB/6 CWB.

34

7

Variable Refrigerant Flow System

TM

The VRF s quality features

Cassette Type (Compact) / Cassette Type Model

Cassette Type (Compact) AU9 AU12 AU14

AU7

AU18

Cooling Capacity

Heating Capacity

VRF differs from traditional ventilation and chiller systems being an economical multi air conditioning system that has the ability to exactly match air conditioning to the needs of the space. Whether operating continuously as required within commercial buildings and public facilities or with large load variations for hotels, etc the VRF maintains optimum operation for that building. That means optimum comfort for the occupants at minimum energy expenditure.

kW

2.15

2.80

3.60

4.00

5.00

5.70

7.05

8.80

10.5

12.7

14.1

7,400

9,600

12,300

13,700

17,100

19.500

24.100

30,000

35,800

43,400

48,100

kW

2.45

3.10

4.10

4.50

5.45

5.80

7.85

9.10

10.7

13.7

15.8

BTU / h

8,400

10,600

14,000

15,400

18,600

19,800

26,800

31,100

36,500

46,800

53,900

W

28

52

50

104

124

140

175

190

219

A

0.13

0.23

0.22

0.60

0.64

0.67

0.92

0.94

0.95

A

0.15

0.27

0.26

0.72

0.77

0.80

1.10

1.12

1.14

530

580

640

1,000

1,100

1,200

1,500

1,650

1,780

Fan Speed

Med

480

520

540

840

940

1,050

1,300

1,450

1,550

Low

410

460

470

700

780

840

1,100

1,200

1,300

High

630

690

750

450

490

540

580

620

680

570

610

640

390

430

480

500

550

580

480

540

540

330

360

390

420

470

500

9

10

15

38

41

44

42

44

46

48

49

52

35

37

38

38

42

44

44

47

48.5

31

34

35

35

39

41

41

43

45

Med

m3/h

r.p.m.

Low W

Fan Motor Output High

Others Noise Level (Sound Pressure)

Med

dB (A)

Low Fan Type x Q'ty

Dimensions (H x W x D)

mm

Net

230 x 570 x 570

246 x 830 x 830

296 x 830 x 830

280 x 710 x 750

385 x 1,045 x 1,015

435 x 1,045 x 1,015

18

34

40

23

45

kg

Gross Pipe Size

Setting size

Liquid

mm 9.52

9.52

12.70

Cooling

18 to 30

C

16 to 30

Heating

5.72 (Unit : m )

19.05

15.88 Flare

Pipe Connection Method Operation Range

53

6.35

Gas

Save space by installing in tandem.

90

Plate Fin Coil Net Gross

Weights

42

Turbo x 1

Heat Exchanger

Compact Size

AU54

Current

Air Circulation

System installation could not be easier, simply connect the refrigerant piping and data transmission line. Repositioning indoor units is just as easy.

AU45

BTU / h

High

Easy Installation

Cassette Type AU30 AU36

Input

Max. Current

VRF

AU25

220-240V~50Hz

Power Source

Economical Operation

AU20

2

Offering one of the smallest footprints available the outdoor unit provides 84kW(28kW X 3) capacity within a very tight space.

Duct Type (Compact) / Duct Type VRF

Others

Model

kW

2.15

2.80

3.50

4.00

5.30

7.05

8.80

10.5

12.7

BTU / h

7,300

9,600

11,900

13,700

18,100

24,100

30,000

36,000

43,500

2.45

3.10

4.10

4.80

5.60

7.85

9.10

10.7

13.7

8,400

10,600

14,000

16,400

19,100

26,800

31,000

36,500

47,000

Input

W

40

Current

A

Air Circulation

Fan Speed

m3/h

240

265

315

1.06

1.16

1.44

0.24

0.27

0.32

0.84

1.58

1.58

1.84

340

420

460

640

750

1,200

1,650

2,000

2,200

0.25

430

560

700

1,100

1,550

1,800

2,000

360

390

480

640

1,000

1,350

1,600

1,800

High

780

960

640

840

960

890

1,240

1,280

1,320

720

880

610

740

900

820

1,140

1,200

1,270

660

810

580

650

840

745

1,040

1,130

1,200

12

14

16

18

21

70

31

35

28

34

36

44

47

49

28

33

27

32

35

42

45

47

26

31

26

30

33

40

43

45

Med

r.p.m.

W High Med

dB (A)

Fan Type x Q'ty

Sirocco x 1

Plate Fin Coil

Gross

mm

Net Weights Pipe Size

Gross

kg

217 x 953 x 595

324 x 785 x 686

324 x 1,075 x 686

18

25

43

22

29

53

Liquid Gas

270 x 1,210 x 700

217 x 663 x 595

300 x 1,300 x 790

6.35 mm

9.52

Pipe Connection Method

45 55 9.52

12.70

15.88

19.05

Flare Cooling

Operation Range

275

Sirocco x 2

Heat Exchanger Dimensions (H x W x D)

Service Tool monitors the entire VRF system. Extensive monitoring and analysing functions. . Operational status can be checked and analysed to detect even the smallest abnormality. . By storing system operation status in a PC, data can be checked even when offline.

155 0.68

390

Net

Service Tool [Software] Model : UTR-YSTC

62 0.27

290

Low

VRF maintenance is easy and simple! Constant monitoring by a PC and integral software service tools can predict faults enabling the service engineer to rectify before a failure occurs.

50 0.23

320

Fan Motor Output

Noise Level (Sound Pressure)

34 0.20

Low

Med

Low

Others

43 0.21

A High

VRF

AR45

kW

Max. Current

The VRF allows the height difference between outdoor and indoor units to be as much as 50m. Consequently for a 15 storey building, for example, all of the outdoor units can be installed out of the way on the roof, freeing-up valuable interior space.

Duct Type AR30 AR36

AR25

BTU / h

Heating Capacity

Free-up Valuable Space

AR18 220-240V~50Hz

Power Source Cooling Capacity

Easy Maintenance

Duct Type (Compact) AR9 AR12 AR14

AR7

Heating

18 to 30 C

16 to 30

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating : Indoor temperature of 20 CDB/(15) CWB, and outdoor temperature of 7 CDB/6 CWB.

8

33

Variable Refrigerant Flow System

TM

Specifications

HEAT PUMP & COOLING ONLY SERIES

Heat Pump / Cooling Only Type Refrigerant Type : R407C Model

AO90 TPCMF

AO72 TPCMF

AO90 EPCMF

28.0

22.4

28.0

31.5

25.2

9.03

7.23

8.50

7.64

Power Source Total Capacity Total Input Watts E.E.R.

Refrigerant Type : R22 AO72 EPCMF

Air Circulation

kW

Heating Cooling

kW

Heating Cooling

W/W

Heating

22.4 -

9.03

7.23 -

3.71

3.30

High

-

22.4

28.0

22.4

31.5

25.2

9.03

7.23

8.50

7.00

-

3.71

3.60

-

9.03

7.23

Flexible Construction Infinitely variable selection from 12 different types and 45 models of indoor unit plus 9 outdoor units. The outdoor unit is capable of handling 130% capacity, easily accommodating future system changes and expansion.

9800

System upgrade network parts

Propeller x 2 Motor Output

W

150 x 2

kW

1.5/3.4/4.9 1.5/2.5/4.8 1.5/3.4/4.9 1.5/2.5/4.8 1.5/3.7/5.0 1.5/2.5/4.8 1.5/3.7/5.0 1.5/2.5/4.8 1,380 x 1,300 x 650

mm

1,535 x 1,400 x 770

Net

kg 380V

Noise Level (Sound Pressure)

415V

dB (A)

313

307

312

306

323

307

320

304

349

343

348

342

359

343

356

340

55

54

55

54

55

54

55

54

57

56

57

56

57

56

57

56

Type

R407C

Charge

kg Liquid

Size Pipe

Suction Gas

Max Length

9

10

R22 10

9

10

9

10

9

12.70

mm

28.58 50 -15 to 52

Cooling

C

Heating

CD-ROM (Software)

Network Convertor (LONWORKS

Model : UTR-YRDA (Option)

Model : UTR-YLLA (Option)

Model : UTR-YLBA

This network convertor is to be used for connecting single split system or group remote controller with the VRF system.

By using the UTR-YLLA, the VRF system can be centrally controlled or monitored from a BMS with a LONWORKS interface.

The central control of maximum 1600 indoor units can be realized by connecting the VRF system to the BACnet , a global standard of the open network

-15 to 21

21 to 52

-

-15 to 21

Comparison with the features between VRF and other system

Refrigerant Type : R407C

Model

AO90MPBMF

kW

Heating Total Input Watts

E.E.R.

Cooling

kW

Heating Cooling

W/W

High

r.p.m.

Low

Motor Output

Net

150 x 2 1.5 / 3.4 / 5.0

mm

Net

kg dB (A)

kg

Discharge Gas

mm

313

57

13

19.05 28.58

Suction Gas

100

Max. Length

Heating

1,535 x 1,400 x 770

12.70

Liquid

Cooling

1,380 x 1,300 x 650

R407C

Charge

Max. Height

Energy Saving

350

Type

Size

Heat Carrying Capacity

49 kcal/kg (10 times higher than chiller)

5 kcal/kg

Energy Efficiency

High Energy Efficiency Direct heat transfer from refrigerant to room air

Less Energy Efficiency 1st. stage heat transfer : From refrigerant to water 2nd. stage heat transfer : From water to room air

Overall Heat Transfer Efficiency

High Between refrigerant & room air

Low Between water & room air

Operation Time

Short (To reach set room temperature)

Long (To reach set room temperature)

Energy Transmission Loss

Low Heat loss through connecting pipe from outdoor unit to indoor unit

High Heat loss through connecting pipe from chilled water unit to indoor fan coil unit

System Efficiency (Partial Load Operation)

High (Refrigerant flow reduced due to compressor power reduction)

Low Compressor power consumption reduced but constant water circulation pump consumption

Heating Operation Performance (Below 0 C)

Sufficient (Discharge air temperature from indoor unit above 37 C)

Insufficient (Except connecting water heating boiler)

Flexibility (Choice of Fan coil Unit)

More Flexible

Less Flexible

Maintenance

simpler and easier than "other systems"

Periodic

9,800

Internal Protector (OCR) High Pressure Relief Valve

Noise Level (Sound Pressure)

Operation Range (Outdoor)

730

W

Protection

Pipe

Water

2.98

kW

Gross

Refrigerant

10.0

Propeller x 2

Gross Weights

Refrigerant

9.40

360 m3/h

High

Fan Motor Output

Dimensions (H x W x D)

28.0

Plate Fin Coil

Fan Type x Qty

Compressor

Heat Transfer Media

3.15

Heat Exchanger

Air Circulation

Other system

31.5

Heating

Fan Speed

VRF system

Basic

3 phase, 380 - 415V, 50Hz

Power Source

[Software]

-

Heat Recovery Type

Cooling

)

BACnet Gateway

Software Protection Key

Network Convertor

100

m

Max Height

Total Capacity

*See details on page 38.

Internal Protector(OCR) / High Pressure Relief Valve

Net

Gross

Operation Range (Outdoor)

28.0

360 m3/h

High

Gross

Refrigerant

AO72 APCMF

730

r.p.m.

Low

Protection

Weights

AO90 APCMF

Plate Fin Coil

Fan Motor Output

Dimensions(H x W x D)

AO72 RPCMF

3.10

Fan Type x Qty

Compressor

AO90 RPCMF

3 phase, 380 - 415V, 50Hz Cooling

Heat Exchanger Fan Speed

HEAT RECOVERY SERIES

m C

Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 CDB/19 CWB, and outdoor temperature of 35 CDB/24 CWB. Heating : Indoor temperature of 20 CDB/(15) CWB, and outdoor temperature of 7 CDB/6 CWB.

Additional Benefits

50 -5 to 52 -15 to 21

Note: "Other system" means water chiller system.

32

9

Variable Refrigerant Flow System

TM

For consultants and building des

INDOOR UNIT

The VRF system offers an infinitely variable choice of indoor and outdoor units: 12 types and 45 models of indoor units together with a choice of 9 outdoor units. Plus 2-pipe (heat pump, cooling only) and 3-pipe (heat recovery) systems are available providing inbuilt reliability. VRF offers flexible and quick air conditioning design solutions supported by low running and maintenance costs, particularly when compared to conventional systems.

Design Flexibility Shorten the design time Compared to conventional building air conditioning systems, VRF system design is fast thanks to the simplicity of the outdoor unit, refrigerant piping and data transmission - and the VRF can control up to 100 outdoor units and 400 indoor units. Refrigerant piping between outdoor and indoor units can extend up to 100m in length with a height difference of 50m, making 15-storey buildings easy to accommodate. So, system design is uncomplicated and fast.

Long piping for high-rise buildings Vertical lift between outdoor unit and indoor units : 50m maximum. When outdoor unit is located above indoor unit. When outdoor unit is located below the indoor unit the height difference is 40m maximum. Vertical lift between indoor unit and indoor units : 15m maximum. Actual pipe length : 100m maximum. Equivalent pipe length : 120m maximum. Total pipe length : 200m maximum.

Heat Pump / Cooling Only Heat Recovery

Maximum number of connectable indoor units

Double auto swing feature provides omni-directional air flow control.

Attractive housing with discreet air intake.

Wall Mounted Type

Ceiling Wall Type

Models

Models

AS18 / AS24 / AS30

AW7 / AW9 / AW12 / AW14 / AW18 / AW24 / AW30

Features

Features

Multi air flow

High efficiency

Large independently driven power diffuser used

High output and high efficiency are achieved by using a DC motor.

One outdoor unit can control up to 16 indoor units (28kW) or 13 indoor units (22.4kW) of different types and capacities.

Max. connectable indoor unit

Refrigerant Type

Capacity R407C

Heat Recovery

28.0kW

R22

AO90MPBMF

16

28.0kW

AO90TPCMF AO90RPCMF

16

22.4kW

AO72TPCMF AO72RPCMF

13

28.0kW

AO90EPCMF AO90APCMF

16

22.4kW

AO72EPCMF AO72APCMF

13

Cooling

Connectable capacity of indoor units for one outdoor unit

50 to 130%

Large independently driven power diffuser

1 2 3

2 4 3 6 5

1 0 1

2 3 4 5 6 3 2 1 0

Floor level heating 2 4 3 6 5

1 0 1

(m)

.Equivalent pipe length: 120m maximum. .Total pipe length: 200m maximum.

1

Wide down flow

2 3

Drain pan can be easily removed for thorough washing without re-moving the unit from the wall.

.High efficiency fan construction 7mm Lambda type evaporator improves the airflow path .Large independently driven power diffuser

22.4kW

2 4 3 6 5

1 0 1

2 3 4 5 6 3 2 1 0

(m)

One-touch long-life filter Removable and washable drain pan

Low noise 7 lambda type evaporator

Suppressing the turbulence by providing vertical grooves on the quiet louver and the right/left louver reduces annoying noise. Existing louver

New quiet louver

Large airflow and low noise achieved by top air intake. Outlet louver reduces annoying noise

Large independently driven power diffuser

Up to 13 indoor units for one outdoor unit

Large, wide airflow

4

Low noise

28kW

2 3 4 5 6 3 2 1 0

(m)

Easy maintenance Height difference : 15m max.

Height difference : 50m max.

Actual pipe length : 100m max.

Horizontal cooling

Heating

Swing

10

Introduction of the top air intake reduces the curvature of the air flow path thereby achieving lower air resistance, lower noise and larger air volume. Horizontal concentration and other air direction control

4

Steps

Up to 16 indoor units for one outdoor unit

High efficiency DC motor

Larger, wider airflow

Heat Pump

Cooling Only

7High efficiency heat exchanger

Easy installation

Long-life filter

Larger space at base of housing means extra 15% piping space.

. Long-life filter can be removed with one touch. . Long-life filter extends the cleaning cycle by a factor of three.

Others

Others

Other features include continuation of the functions of the existing wall mounted type.

. Double auto swing . 2-way draining route

. Double auto swing/Right and left, up and down . 2-way draining route . Air purifying filter (Optional parts) 31

Variable Refrigerant Flow System

TM

Ceiling / Wall Mounted (Compact) / Wall Mounted / Ceiling Wall Type

igners

HEAT PUMP & COOLING ONLY SERIES

HEAT RECOVERY SERIES

Flexible Control System Flexible design

Stylish and compact, these elegant wall-mounted units complement any interior decor

An ultra-slim design that offers a variety of installation methods, this indoor unit is lightweight and extremely quiet.

This indoor unit can't be operated in the Heat Recovery Type System. AS7/AS9/AS12/AS14 are only available for wireless remote controller.

Flexibility is enhanced through the ability to connect outdoor units, indoor units and controllers anywhere within the data transmission line.

Refrigerant system

Models

Models

Outdoor units

AB30 / AB36 / AB45 / AB54

AS7 / AS9 / AS12 / AS14

Features

Features

Installation

Compact design Wall mounted

Remote controller line

Maximum connectable number per one transmission line

Wall Mounted Type (Compact)

Concealed

Transmission line (non-polar 2 core)

Indoor unit

Ceiling Type

Open

Outdoor unit

100 400 100

Indoor units

Central remote controller

Control options

Powerful output despite small size This compact wall mounted units have a powerful cooling capacity due to the large high pressure fan and lambda type heat exchanger.

Indoor unit

A variety of control options are available within one VRF system. As the signal receiver is built into the indoor unit a mix of wired/simple/wireless remote controllers can be used simultaneously with the same indoor unit.

Condensate lift-up mechanism H257 x W808 x D187 (mm)

Low noise level Double auto swing and wide air flow Up and down

(AS7)

3

4

4 steps selectable

Fresh air intake

The aerodynamic characteristics of the outlet louver contribute to a very quite indoor unit.

Fan speed

dB(A)

30 26

HIGH LOW

"Group" is possible with only one indoor unit

The "Auto Swing Louver" feature ensures optimum airflow for each of the operating modes.

Steps Swing

Outdoor

Long-life filter

Cooling mode : 2-step ( - ) Heating mode : 4-step ( /

Swin

A

Overlapped "Group" is possible

B

-

)

The removable and washable panel filter is an effective "air cleanser" removing mould and dust from the occupied environment.

Advanced Functions Interfacing system with external equipment An output on the indoor PCB allows an auxiliary fan to be connected, possible to introduce outdoor air etc.

Emergency turn off Function for emergency turn off in case of fire or earthquake, etc.

Indoor unit Ventilation fan or heat recovery ventilation fan

Fan motor relay (DC 12V)

The top panel can also be removed for easy cleaning if neccessary.

C

g

High efficiency, long-life filter extends the cleaning cycle by a factor of two.

30

2 remote controllers (joint use)

[1] Operation of either group A or group B is possible. [2] Simultaneous operation of groups A and B is possible. (Last setting has priority) [3] As shown in drawing "C", "Group" spanning the refrigerant system is possible. [4] The PC Controller software can assign a name to each group.

Cleaning of the indoor unit itself is simple due to design and shape of the casing.

UTR-DPB241

Central control and individual control

Refrigerant system2

Washable panel filter Fresh air

Drain water riser kit

Wired / Wireless Remote Controller

Refrigerant system1

ing Sw

2

Optional parts

Indoor unit

Example of "Group"

This function is used when operating multiple remote controller groups at one time from a central remote controller or PC controller.

Auto swing louver

1

Indoor

Indoor unit

Group control

Optional drain lift-up mechanism allows flexible installation.

5 steps selectable

Indoor unit

Central remote controller

Wired or Simple Remote Controller

Right and left

PC Controller

DC 12V shall be outputted during the indoor fan operation.

Output (DC 12V)

Turn off

Indoor unit

M

Outdoor unit

The whole system can be turn off by the input of contact point.

Input (Contact point)

Central remote controller

11

Variable Refrigerant Flow System

TM

For Installers

INDOOR UNIT

versal Type

Reduced Installation Work Compact size

Space saving Outdoor unit goes into elevator

Dimensions

1,300

800

Installation space For continuous

10mm or more

10mm or more 500mm or more

Offering one of the smallest footprints available the outdoor unit provides 84kW (28kW X 3) capacity within a very tight space.

300mm or more

Protective boards

The outdoor unit can be lifted by crane and set down on the building roof.

10mm or more Top air outlet L1 L2

Front side intake port

FRONT SIDE

Back side intake port

. There is no height restriction for the side wall. . The height(H) of front and rear wall should be less than 1,200mm. . If the height of wall exceeds 1,200mm by h mm, add h mm to the service

Floor & Ceiling Universal Type

Models

Models

AR36(H) / AR45(H) / AR60(H)

AB12 / AB14 / AB18 / AB24

Features

Features

Savings in space and reduction in noise

Flexible installation

Easy installation

10mm or more

10mm or more

High Static Pressure Duct Type

Installed in the ceiling void this model provides savings in space and reductions in noise. A single indoor unit can serve several rooms.

10mm or more

H (1200mm) h

H (1200mm) h

500mm or more

650 (Unit : mm)

A high static pressure duct type indoor unit

The slim and lightweight design allows the unit to be suspended from the ceiling or installed at floor level.

2

Craning into place

For individually

300mm or more

5.72 (Unit : m )

1,300

650 (Unit : mm)

FRONT SIDE

Setting size

1,500

1,380

1,050

Space saving by setting side by side without space in between.

Piping connection

To top

4

Four-direction piping allows a variety of installation configurations. Easy installation and pipe direction setting.

Back

3 1

Front

Right

2

Easy installation by suspension Auxiliary pipe assembly

To rear

space width for L1 and L2. H 1,200 : L1 500, L2 300 H 1,200 + h : L1 500 + h, L2 300 + h

Ceiling

The pipe can be connected in any direction by using the L-shaped auxiliary pipe.

Four-direction pipe

Floor

Hanger bolt

Hanger

Unit

Compact design Symmetrical, slim and compact design

655 (unit: mm)

To side

990

199

Double auto swing

To bottom

Bottom

A combination of up/down and right/left directional swing allows three-dimensional air direction control.

Easy maintenance

Low Piping Costs

Fan motor maintenance can be performed from the top and the bottom. Top access

Simple piping system

Control box cover (Electrical parts access)

RIGHT and LEFT SWING

Maintenance panel (Thermistor access)

1

2

3

4

UP and DOWN SWING 1 3

The simple piping system reduces costs by increased piping flexibility. Cooling Only & Heat Pump Separation tube

4

Heat Recovery Separation tube

Header

Header Maintenance panel (Fan motor access)

Bottom access Outdoor unit

Outdoor unit

RB unit (Single type)

Liquid pipe Liquid pipe

Indoor unit

Discharge gas pipe

Gas pipe Suction gas pipe Indoor unit

12

2

5

Indoor unit RB unit (Multi type)

Indoor unit

Recommended external static pressure : 196 Pa (Max. 300Pa) Outlet chamber Flexible duct Long life filter Remote sensor unit

4 steps selectable

Super vane

High static pressure Optional parts

5 steps selectable

UTD-BC200 UTD-RD202 UTD-LF400 UTD-RS100

Double-flap ‘Super Vane’ with newly developed special configuration boosts air flow sending cool air quickly to every corner of the room.

Auto-closing louver This function is common to all indoor unit types except the duct type.

29

Variable Refrigerant Flow System

TM

HEAT PUMP & COOLING ONLY SERIES

Duct (Compact) / Duct / High Static Pressure Duct / Floor & Ceiling Uni

HEAT RECOVERY SERIES

Easy Wiring Transmission line

Power supply wiring

Non-polar 2-conductor transmission line prevents erroneous wiring.

Choice of installation Can be suspended from the ceiling or placed on the floor

Ultra-slim duct air conditioner for very low ceilings

Duct Type (Compact)

Duct Type

Models

Models

AR7 / AR9 AR12 / AR14 / AR18

AR25 / AR30 / AR36 / AR45

Features

Features

Compact design

Savings in space and reduction in noise

Ultra-slim duct air conditioner for easy installation

Whether installed in the ceiling void or a false ceiling, this model provides savings in space and reductions in noise. A single indoor unit can serve several rooms.

Power supply for outdoor and indoor units is different.

Transmission line

Outdoor unit : 3 4W 380 - 415V 50Hz

Transmission adaptor Transmission line

Indoor unit : 1 2W 220 - 240V 50Hz

Central remote controller

Outdoor unit

Outdoor unit Indoor unit

Outdoor unit Indoor unit

Indoor unit

Flexible installation Suspended installation

Direct installation

Hanger bolts

AR7 / AR9

Anchor bolts

AR12 / AR14 / AR18

Easy to install (Universal type)

Embedded in Ceiling

Service Tool [Software]

Model: UTR-YSTC

Service Tool can monitor the operation of the entire VRF system.

Installation styles Ceiling concealed

PC controller

Hanging from Ceiling

Extensive monitoring and analysing functions

. Operational status can be checked and analysed to detect even the smallest abnormality. . By storing system operation status in a PC, data can be checked even when offline.

Floor concealed

Ultra-slim models for very low ceilings

Easy Maintenance

27cm

Low noise level

Piping can be run in almost any direction

A low noise level has been achieved for each capacity Model Static pressure (Normal/Max.)

Volume of air-flow (High/Low)

Noise level (Low speed)

7

9

Pa

14

18

m3 / h

340/290

420/360

460/390

640/480

750/640

dB(A)

26

31

26

30

33

Remote sensor unit

27cm

0 / 39.6

Optional parts

28

12

Coupling pipe assy

UTD-RS100

Control box

Optional parts

Drain port

Flange (square) Flange (round) Flexible duct Long life filter Remote sensor unit

UTD-SF045T UTD-RF204 UTD-RD202 UTD-LF270 UTD-RS100

Operating display (outdoor unit) By indicating the operating status and details of failures on a PCB in the outdoor unit, better service and quick and easy maintenance are possible.

Easy replacement A pull-out plate ensures easy compressor replacement if necessary.

Pump down control Pump down can be performed from the outdoor unit using the switch on the PCB.

Operation display

13

Variable Refrigerant Flow System

TM

VRF structure and features ensure

INDOOR UNIT

Flexible Control System Features of control system 1. Reduced wiring as all system equipment accommodated on a single transmission line (non-polar 2-conductor). 2. Total wiring length (total length of transmission line) can be extended up to 2000m (by using signal amplifier units). 3. Maximum of 400 indoor units can be connected. 4. Indoor units can be controlled by wired, simple, wireless, group, central remote controller or PC controller. 5. Central control of single split type models (with exceptions) or big multi type air conditioners is possible from a central remote controller or PC controller. 6. Model combinations are dictated by the building s needs and not the system. 7. The 'simple' remote controller is ideal for installations such as hotel guest rooms.

Slim cassette, designed for limited ceiling space

1. Individual operation of the indoor units ensures that the failure of one does not affect the whole system. 2. Maintenance efficiencies are raised through the connection of a PC anywhere on the data transmission line. 3. Error codes can be clearly displayed on the wired remote controller, simple remote controller, group remote controller, central remote controller or PC controller.

Models

AU20 / AU25 / AU30 AU36 / AU45 / AU54

Slim Type

Air Conditioning Individual Control Wired Remote Controller

Group Remote Controller Network Convertor

3 6 9 12 15 18 21

General-purpose building control computer Connectable to *1 various sized BMS/BAS

Slender setting Ha

Indoor unit

Wireless Remote Controller

Transmission Adaptor

Standard setting

Slender setting

UTR-YTMA

Ha

Hb

AU20 / AU25 / AU30

235

200

AU36 / AU45 / AU54

285

250

UTB-YCA / UTB-GCA

UTB-YVB / UTB-GVB (Symbol type)

PC Controller Transmission Adaptor

Simple Remote Controller

3-way

4-way

Compact body ensures space saving installation. A slender fit option is available where ceiling void space is limited. Standard setting

7

UTB-YUB / UTB-GUB / UTB-TUB

Central Remote Controller

Outdoor unit

SU MO TU WE TH FR SA

UTR-YRDA UTB-YDB / UTB-GDB

System

2-way

Hb

Air Conditioning Central Control

4 steps swing

4 steps swing

2~4 way air flow system Select 2-way, 3-way or 4-way air flow to suit your needs.

Flexible installation Building Management

4 3 2 1

1 2 3 4

Features

Configuration of control system

Swing Steps

4-step swing Auto air flow direction and auto swing

Cassette Type

Control system reliability

Comfortable air flow

Wide air flow Larger air flap distributes the outlet air flow a longer distance in the horizontal direction.

Duct connection hole opening Fresh air can be introduced through this opening.

Conditioned air can be distributed by means of a distribution duct.

Distribution duct

Two-way

Fresh air

One-way

Distribution duct

Easy maintenance

UTR-YTMA UTR-YOTB [Software]

Network Convertor (BMS / LONWORKS )

UTB-YPB / UTB-GPB / UTB-TPB

Signal Amplifier

Simple Remote Controller

UTR-YRPC

Improved noise level and air distribution Noise output has been dramatically lowered. . Improved turbo fan shape (aerodynamic design) . Expanded air distribution . Low internal resistance . Moulded fan motor

UTR-YLLA

USB Adaptor*2 (Field supplied)

Card-key

Network Convertor

External switch controller

UTR-YRDA

UTR-YLBA [Software]

(Field supplied)

Web Monitoring Tool VRF System Side (User Side)

Remote Side

Transmission Adaptor UTR-YTMA

or

or *3

USB Adaptor (Field supplied)

(Internet Explorer) UTR-YMSA [Software]

14

Transmission Adaptor UTR-YTMA

UTR-YESA

Service Tool

USB Adaptor (Field supplied)

Remote controller line (Single System) UTR-YSTC [Software]

*1. BMS/BAS: Building Management System / Building Automation System. Building Management System is supplied by the other vendors. *2 USB Adaptor is XLON USB Adaptor of DH electronics company. *3. U10 USB Network Interface - TP/FT-10 (Echelon corporation)

Long-life filter

Simple maintenance

High efficiency, longlife filter extends the cleaning cycle.

The control box is easy accessible for maintenance work. Wide opening for easy access.

High ceiling mode (air flow up) and low-noise (air flow down) can be switched according to the height of the ceiling and other conditions by means of a PCB DIP switch.

Detachable, washable filter and intake grille.

Standard Suitable ceiling height (m)

LONWORKS Network BACnet / IP

2.5-3

High 1 ceiling High 2 ceiling

Low ceiling

more than 3.5

less than 2.5

3-3.5

Draught prevention Movement of the flap angle can be changed via a simple switch during installation, thereby preventing uncomfortable draughts.

Transmission line (LONWORKS Network) Transmission line (Interlink Cable) Remote controller line

*3

Air-flow volume can be switched

Long-life filter

UTB-YRA / UTB-GRA / UTB-TRA

Condensate pump lift to 800mm

Normal position 800mm

BACnet Gateway

Draught prevention position

Flap angle 36 - 65

Flap angle 25 - 65

27

Variable Refrigerant Flow System

TM

flexible control

Cassette (Compact) / Cassette Type

FLEXIBLE CONTROL SYSTEM

Construction of Wiring System Wiring configuration of the control system is made of power source wiring, transmission wiring and remote controller wiring.

System Diagram

PC Controller .Maximum 400 units can be controlled .Air conditioning control .Operation monitoring .Failure diagnosis .System set-up .Billing calculation

Transmission adaptor

Transmission line line is non-polar 2-conductor.

Interlink cable

Outdoor unit

3A

Indoor unit

1 50Hz 220 - 240V

Compact design for easy installation and maintenance

3A Network convertor UTR-YRDA

Cassette Type (Compact)

Refrigerant system 1

Models

AU7 / AU9 / AU12 / AU14 / AU18

1 50Hz 220 - 240V

Group remote controller .Maximum 8 units can be controlled

PC controller

Central remote controller .Maximum 16 units can be connected. .One central remote controller can connect up to 64 groups / 400 indoor units.

Central remote controller

20A 1 50Hz 220 - 240V

40A

Group remote controller

3 4W 50Hz 380 - 415V Remote controller line Maximum 4 units can be controlled

Features Refrigerant system 64

Compact size

Comfortable air flow

Compact grille fits European ceiling panel (600 x 600 mm).

4-step swing Auto air flow direction and auto swing

Punch Hall grille

1 50Hz 220 - 240V 40A

20mm 245mm

650mm

2 remote controllers Indoor unit can be controlled from both remote controllers.

Network convertor UTR-YRDA

2-way

Big multi system

3-way

4-way

Refrigerant system Indoor units

By placing the electrical component box inside the unit easy maintenance is assured.

Electrical component box (Built-in)

Outdoor units

Low noise

400mm

Normal position

Draught prevention position

Flap angle 36 - 65

Remote controller line

Transmission line (non-polar 2-conductor)

Power source / signal line

Power supply line

Single system

Network convertor UTR-YRDA

100 400 100

Combination of local remote controller Wired, wireless and simple remote controllers can be used jointly.

It is possible to control not just the air conditioning system but the whole building management system including lighting and electrical facilities, hydraulic systems, fire alarm interface, security systems, etc.

Monitoring & Controlling for VRF system

Movement of the flap angle can be changed via a simple switch during installation, thereby preventing uncomfortable draughts.

26

Indoor units can be controlled by combining with Card-key switch such as hotel room.

Building Management System (BMS) Compatibility

7 blades fan

298mm

Large air flow at reduced noise output achieved by incorporating a large diameter variable pitch turbo fan.

Draught prevention

Condensate pump lift to 400mm

Simple remote controller

External switch controller

Maximum connectable number per one transmission line

Easy maintenance

Detachable, washable filter and intake grille.

System without remote controller Together with central remote controller, it is possible to build non remote controller system.

Wireless remote controller

2~4 way air flow system Select 2-way, 3-way or 4-way air flow to suit your needs.

Wide opening for easy maintenance.

Simple remote controller

Card key

3 4W 50Hz 380 - 415V

570mm

650mm

Wired remote controller

20A

Security system

Lighting facilities

Network convertor / Gateway

Hydraulic systems

BMS console

Automatic fire alarm interface

Parking lot facilities

Flap angle 25 - 65

Ventilation system

15

Variable Refrigerant Flow System

TM

Controller features

INDOOR UNIT

Air conditioning central control

PC Controller [software]

Floor & Ceiling Universal Type

Ceiling Type

Wall Mounted Type (Compact)

Wall Mounted Type

Ceiling Wall Type

UTR-YOTB [Option]

High performance and optimum control system for various building applications

.Up to 400 indoor units/400 groups/64 remote controller groups can be connected into one system for large scale buildings or hotels.

This indoor unit can't be operated in the Heat Recovery Type System.

.Provides powerful functions for building air conditioning management, including automatic calculations of electrical costs and numerous data management functions, as well as standard equipment monitoring and control.

Model AB12 / AB14 / AB18 / AB24

Model AB30 / AB36 / AB45 / AB54

Model AS7 / AS9 / AS12 / AS14

Model AS18 / AS24 / AS30

Model AW7 / AW9 / AW12 / AW14 / AW18 / AW24 / AW30

see page 29

see page 30

see page 30

see page 31

see page 31

Functions Central building monitoring and control

. Detailed settings can be programmed for each whole building/group/remote controller group or individual indoor unit. . The PC and central remote controller can be used together, allowing system control from two or more locations if required. Central control The 6 functions of the standard controller can be locked from the PC: all functions, timer mode, operating mode, temperature setting, filter reset, on/off. All functions can be controlled via the PC Controller only.

Auto mode (Priority-mode changer) Auto mode function automatically switches between cooling and heating modes based on the temperatures set and the room temperature detected by the master indoor unit. Other operating indoor units can be operated in the same operating mode as the master indoor unit.

Operation Control

User-friendly Operation . Runs under Windows 2000 and Windows XP Professional / Home so is as easy to use as a standard PC. . Operational status can be colour-coded for instant recognition: On/green, Off/red, test/orange, error/flashing. . Operational status can be displayed to user's preference. Linking with external control equipment is possible.

Prevents wireless remote controller interference

Simple external appearance by auto shut flap

Diverse air conditioning control systems linked with various equipment inside the building can be built by using the external I/O port.

The signal cord of the wireless remote controller can be switched and prevents erroneous operation by interference between adjacent indoor units.

Gap-free, flat, and simple external appearance by closing of the flap when operation stops.

Symmetrical design

16

Rotating 3-D Display

Floor Layout Display

List Table Display

When monitoring and controlling the operation by whole building.

When monitoring and controlling the operation by each floor or group.

When monitoring and controlling each unit in detail.

Left and right symmetrical design harmonizes with any interior design and creates a tranquil atmosphere.

25

Variable Refrigerant Flow System

TM

Full Range of Indoor Units

FLEXIBLE CONTROL SYSTEM

A full and complete range of indoor units is available

Type Cassette Type (Compact)

Cassette Type

Duct Type (Compact)

Duct Type

High Static Pressure Duct Type

Calculating electrical costs

Error display

. Total electrical costs, billed for multiple indoor connected to the charge Slim Type

. .

meter for air conditioning, is apportioned according to the accumulated refrigerant time and indoor unit capacity. Allows accounting for special rates (e.g., for night or weekend use). Calculations can be printed as final bills.

Audible alarms are accompanied with explanatory text. Up to 100 alarms can be recorded for each piece of equipment, particularly useful during maintenance.

Electric bill

Capacity

Model AU7 / AU9 / AU12 / AU14 / AU18

Model AU20 / AU25 / AU30 ( Slim Type ) AU36 / AU45 / AU54

Model AR7 / AR9

see page 26

see page 27

see page 28

Model AR12 / AR14 / AR18

Model AR25 / AR30 / AR36 / AR45

Model AR36(H) / AR45(H) / AR60(H)

see page 28

see page 29

Block's(Tenant) bill

Bill Block(Tenant) A

(kW)

(BTU/h)

17.00

60,000

M Meter

Input data Apportioned charges

ELECTRICITY COMPANY

14.10

54,000

12.70

45,000

10.50

36,000

8.80

30,000

Slim Type

7.05

25,000

Slim Type

6.80

24,000

5.70

20,000

5.30

18,000

4.05

14,000

3.60

12,000

2.80

9,000

2.15

7,000

Block(Tenant) B

Error Warning

Operating record PC controller

Block(Tenant) C

BUILDING

The operating status of indoor units and accumulated operating time of outdoor units can be recorded and a daily or monthly report produced.

Schedule control Annual schedules can be set for each remote controller group. Start/stop, operating status, remote controller prohibition and temperature settings can be recorded up to 72 times per day at 10 minute intervals for up to 6 configurations for each remote controller group. Setting over midnight is possible. Schedule Control Holiday settings including public holidays for a complete year can be programmed. The 6 functions of the standard controller can be locked by schedule control.

Slim Type

Operation Record

Pattern setting It enables to recognize operation status, such as ON/OFF, operation mode and set temperature, as a combination pattern. An arbitrarily pattern operation can be done with just one button clicking.

Easy Installation . Simple connection by Transmission Adaptor and Interlink cable ( Interlink cable field supplied ).

. Simple installation of software using only the CD

Interlink cable

supplied.

Indoor units Transmission Adaptor

Common features

Room temperature feedback control

Energy saving operation

Auto-Changeover

Comfortable temperature control can be achieved by feedback control of intake air temperatures and the opening of electronic expansion valve.

Energy saving operation is possible by changing the operation capacity according to the remote controller's setting.

The unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.

COOLING operation : The thermostat setting is automatically raised 1 C every 60 minutes, until the thermostat is raised a total of 2 C.

Room-temperature feedback control

+2 C

COOLING

Conventional control Feedback control

HEATING operation : The thermostat setting is automatically lowered 1 C every 30 minutes, until the thermostat is lowered a total of 4 C.

Requirements of PC for this software Operating System Personal Computer

+1 C Set Temp.

Set temp.

24

Indoor units

Software Hardware

-1 C

HEATING

-2 C : Comp. ON

: Comp. OFF

*It is only available for heat recovery type.

Packing List

CPU HDD Memory Interface Accelerator

AT compatible machine that runs Microsoft Windows Microsoft Windows 2000 Professional (English version / Service pack3 or later) Microsoft Windows XP Professional / Home (English version / Service pack1 or later) TM TM Intel Pentium / Celeron , AMD Athlon / Duron 1GHz or higher 4GB or more 256 MB or more Serial port and USB port Requires that the internal graphics accelerator be compatible with Microsoft DirectX 7.0 or later Adobe Acrobat Reader 4.0 or later Interlink cable (D-sub 9pin female connector) (Parts No.: KRS-L09-4K) [Field supplied]

Software protection key / CD-ROM / Transmission Adaptor

17

Variable Refrigerant Flow System

TM

Controller features

FLEXIBLE CONTROL SYSTEM

Air conditioning central control

Central Remote Controller

Simple Remote Controller UTB-YPB / UTB-GPB / UTB-TPB [Option] UTB-YRA / UTB-GRA / UTB-TRA [Option]

UTB-YCA / UTB-GCA [Option]

Simple remote controller concentrating on the basic operations.

.Up to 4 indoor units can be controlled with one remote controller. .Suitable for hotels or offices which have many visitors coming in and going out

Functionality in a compact housing with built-in weekly timer

and do not require detailed functions.

. Up to 400 indoor units/400 remote controller groups/64 groups can be .

controlled by one system. Up to 16 central remote controllers can be connected into one system allowing operation and monitoring to be achieved from the central control room, at each floor, by each tenant, or in the plant room.

UTB-YPB / UTB-GPB / UTB-TPB

UTB-YRA / UTB-GRA / UTB-TRA

Dimension (H x W x D) (mm)

User friendly operation

Back ground light

.Backlight enables easy operation in

.Concentrates on the basic operations such as On/Off, Fan Control, Ope-

a darkened room.

ration Mode Switching, and Temperature Setting. A large Start/Stop button is provided in the centre of the remote controller unit for easy operation. Standard remote controller enable to use together. Diagnostics are carried out during the stop mode following an error display.

Functions

120 x 75 x 14

.

.The backlight is lit during the button

. .

operations, and also 10 seconds more in operation mode and 5 seconds more in stop mode.

Simple installation work

Control up to 400 indoor units

.Central remote controller can control the system by selecting All Groups, User Defined Groups or Individual Remote Controller Groups .Accurate control of functions such as Start/Stop, Operating Mode, Temperature, and Air Velocity ensures occupancy comfort. Controllable method

Central control

.Can be mounted on the European Mounting Box (Installation dimension: 60mm) or the JIS Built-in Box (Installation dimension: 83.5mm).

Model Operation On/Off Fan control Operation mode Temp. setting

JIS built-in box

All

Group

Functions

European switch box

The 6 functions of the standard remote controller can be locked from the Central Remote Controller: all functions, timer mode, operating mode, temperature setting, filter reset, on/off. All functions can be controlled via the Central Remote Controller only.

UTB-YPB UTB-GPB UTB-TPB

UTB-YRA UTB-GRA UTB-TRA

External Switch Controller UTR-YESA [Option]

.ON/OFF, Temperature, Fan speed and Operation mode can be switched by a combination with Card-key switch equipped in facilities such as hotel room. .Switching of air conditioner can be controlled by connecting other sensor switches.

Individual

*Card-key and other sensor switches are available as a field supplied parts.

Dimension (H x W x D) (mm)

Easy Operation . Control functions are divided into three clusters: Timer Control, Central Control and Operational Control, which are clearly displayed. . A large liquid crystal display clearly indicates which indoor unit is currently in operation.

Electrical wiring Card-key

Sensor SW

Indoor Unit

1

2

3

E

Remote Controller Line

Card-key (Field supplied)

COM SW1 SW2

1

3

Sensor SW (Field supplied)

E COM SW1 SW2 External input

3

4

Combination of " 1 " + " 2 "

Up to 2 controllers

Individual Control Mode TIMER CONTROL AREA

18

2

EXTERNAL SWITCH CONTROLLER

2 Group Control Mode

Indoor Unit

Remote Controller Line

External input

EXTERNAL SWITCH CONTROLLER

All Control Mode

120 x 75 x 30

CENTRAL CONTROL AREA

OPERATION CONTROL AREA

2 Wired remote controllers

2 Simple remote controllers

Wired + Wireless remote controller

Simple + Wireless remote controller

Wired remote controller

Wireless remote controller

Simple + External switch controller(card key)

23

Variable Refrigerant Flow System

TM

Controller features

FLEXIBLE CONTROL SYSTEM

Air conditioning individual control

Wireless Remote Controller

Built-in weekly timer

UTB-YVB / UTB-GVB [Option] Symbol type

. The timer function, which can control up to 400 indoor units,

Simple Operations with a Choice of 4 Daily Timers Dimension

(H x W x D) (mm)

provides detailed scheduling for each remote controller group. A simple approach to system configuration reduces wiring costs. 1. Possible to set different ON / OFF time twice a day for each day of the week. 2. Possible to set time in 10 minutes steps. 3. Time operation for a reserved day can be cancelled temporarily by pressing the "DAY OFF" button in advance. 4. Time setting can be carried over to the next day. 5. Copy and Paste can be used for time settings for each day.

.

158 x 56 x 20

UTB-YVB / UTB-GVB Symbol type

Built-in daily timer Select from 4 different timer programs : On / Off / Program / Sleep

Weekly schedule

Program Timer : The program timer operates the ON and OFF timer once within a 24 hour period

On

Sun

Cooling operation/dry operation

Heating operation

When the sleep timer is set, the set temperature automatically rises 1 C every hour. The set temperature can rise up to a maximum of 2 C.

When the sleep timer is set, the set temperature automatically drops 1 C every 30 minutes. The set temperature can drop to a maximum of 4 C. 1C

60min.

2C

3C

Tue

Wed

Thu

Fri

Sat

Up to 62 error codes can be displayed. The last 2 error codes can be displayed, allowing easy inspection, service and maintenance.

. The controller can be installed on any flat surface. . The control panel and transmission adaptor unit can be built into the wall or exposed.

Easy installation and operation mitting range.

Code change Confusion

A

A

B

B

C

C

3. Press the MASTER CONTROL button again to end the code change.

D

Power Supply 220-240V (Use a 3A or more fuse)

22

1H 25 C

23 C 22 C

0.5H

21 C

0.5H

20 C 0.5H

19 C

1.

Wireless remote controller

Setting Example (2) Behind ceiling

Transmission Adaptor

Possible to extend up to 5m. (Max) (optional service parts)

Control Panel Wall

Control Panel

Transmission Adaptor

UTB-YCA / UTB-GCA

2.

Power Consumption (W) Fuse Capacity (A) Dimension (H x W x D)(mm)

Up to 4 indoor units Simple remote controller

Control Panel

Transmission Adaptor

DC 12V

220-240V 50-60Hz Single phase

4.8

4.8

3

3

143 x 296 x 22

107 x 288 x 100

550

1300

Packing Size (H x W x D)(mm)

-

145 x 330 x 190

Transmission Line

-

Shielded Non-polar, 2 core cable

Weight (g) Up to 4 indoor units

Setting Example (1)

Specifications

1

Wired remote controller

26 C

Control Panel

Standardization and simultaneous use of remote controllers Up to 4 indoor units

Connecting cable

Transmission Adaptor

Power Supply

Wired, simple and wireless remote controllers can be used with the same indoor unit. Simultaneous use is also possible. A separate signal receiver kit is not required as the remote controller signal receiver is built into the indoor unit body.

During HEATING operation When the ENERGY SAVE is pressed, the thermostat setting is automatically lowered 1 C every 30 minutes, until the thermostat is lowered a total of 4 C.

Transmission line

1. Press the MASTER CONTROL button for more than five seconds to start the code change. 2. Press the (+) or (-) button to select the desired code. A B C D

D

27 C

Simple and Convenient Installation

90min. Timer setting

. Wide and precise trans-

During COOLING operation When the ENERGY SAVE is pressed, the thermostat setting is automatically raised 1 C every 60 minutes, until the thermostat is raised a total of 2 C.

Memory : Central remote controller maintains original settings for indoor units. This data can easily be transmitted to the system even after the operating conditions have been changed.

4C

can be installed separately.

mix-up. (Up to 4 codes can be set.)

Energy Saving Operation :

Energy save

. For flexibility in installation, the main . Code selector switch prevents indoor unit

Anti Freeze : In cold regions, room temperature OFF OFF drops at night. This function pre8C vents freezing of the water and other parts. When the room temON ON 5C perature drops to 5 C or less the heating is automatically switched on. Then the room temperature reaches 8 C the heating automatically switched off.

Energy save

Error display

60min. 1C

Mon

Operation : Monday~Friday 8:00~12:00 and 13:00~18:00

30min.

2C

Example : Office

Off

Sleep Timer : The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling and heating while sleeping.

Timer setting

Advanced functions

Packing List

Control Panel / Transmission Adaptor / Connecting Cable

19

Variable Refrigerant Flow System

TM

Controller features

Controller features

Air conditioning central control

Air conditioning individual control

FLEXIBLE CONTROL SYSTEM

Group Remote Controller

Wired Remote Controller

UTB-YDB / UTB-GDB [Option]

UTB-YUB / UTB-GUB / UTB-TUB [Option]

Group control of indoor units with simple operation

Simple Operation with Built-in Weekly / Daily Timer Up to 4 indoor units can be controlled with 1 controller. Up to 2 wired remote controllers can be connected to 1 indoor unit.

Up to 8 indoor units can be controlled by a single controller. Up to 64 Group Remote Controllers can be connected in a single VRF system. Network Convertor (UTR-YRDA) is required to connect Group Remote Controllers to an VRF system.

Dimension (H x W x D) (mm)

120 x 120 x 17

Build-in thermo sensor doesn't work in S series system.

Control up to 8 indoor units

High performance and compact size

.Control and monitoring of up to 8 indoor units is possible with a

.ON/OFF, operation mode, set temperature and air flow can

single Group Remote Controller.

.Up to 64 Group Remote Controllers can be connected in a single VRF system. 4 Group Remote Controllers can be connected to a single Network Convertor (UTR-YRDA). A single Network Convertor (UTR-YRDA) covers 2 refrigerant circuits.

.

be controlled / monitored centrally or individually. Central control

ON/OFF control

Weekly timer

Weekly timer : Two ON/OFF times can be set for each day of the week. Easy-to-understand time bar display

Weekly timer

Setback timer

Screen after setup

SU MO TU WE TH FR SA

7 3 6 9 12 15 18 21

Setup screen example (Set to Wednesday: 8:00 to 20:00.)

0

Office & Hotel building (Small class)

Built-in weekly timers The WEEKLY TIMER is provided as a standard function. 1. The timer can be set up for up to 4 times/day. (On/Off, operating mode, set temperature) 2. Allows separate settings for each day of the week.

Group remote controller 1 for office floor Office room Network convertor

ON/OFF switching

Cooling/Heating switching

Wireless Remote Controller Wired Remote Controller

Built-in timers

This wired remote controller incorporates three primary functions into a single unit.

Wired remote controller

.

1 2 Group remote controller

Powerful features and compact size

Meeting room

Group remote controller 2 for office floor

Temperature switching

Temperature switching

(Peak cut)

(Anti-freeze)

3

6

9

12

24 C 15

18

21

Setback timer : Allows the user to set temperatures for two time spans over the course of each day of the week.

Easy-to-understand operation

Setup screen example (Set from Sunday to Saturday: 12:00 to 15:00, 28 C.)

Diverse timer control The operation / display section are zoned into a timer area and an operation area. Also, the ON/OFF timer uses a remaining time feature and allows diverse timer settings corresponding to the application.

0

3

6

9

28 C 15 18

12

21

At "Weekly timer" + "Set back timer" setup :

24 C

28 C

24 C

Guest room

Operation area

Timer area

0

3

6

9

24 C

28 C 12

15

18

21

Time

Energy Saving Operation Stop setting

Wired Remote Controller Simple Remote Controller

Diagnosis check function

Lobby

There are two methods for interrogating the cause of failure when a malfunction occurs:

Up to 8 indoor units

Energy saving operation is possible by changing the operation capacity according to the remote controller's setting. (See details on page 24)

Malfunction diagnosis function :

Specifications Model Power Supply Dimension (mm)

20

Network Convertor

UTB-YDB / UTB-GDB

UTR-YRDA [Option]

DC 12V

220-240V 50-60Hz

Height

120

67

Width

120

288

Depth Weight (g)

Group Remote Controller

17

211

160

1,400

Should an abnormality occur during system operation, the error code of the connected indoor units can be displayed.

Abnormalities occur

Press for more than 5 seconds.

Error code

Remote controller address

Error history : The last 16 error codes can be accessed via the controller. This is useful for troubleshooting system abnormalities and helpful for determining error causes.

Simple installation work Can be mounted on the European Mounting Box (Installation dimension: 60mm) or the JIS Built-in Box (Installation dimension: 83.5mm). European mounting box

Error history number Error code

Press for more than 5 seconds.

Remote controller address

JIS built-in box

21